Journal of Clinical Medicine · 2023 · 16 citations · 25 references
MedicineGynecologyRadiologyDiagnostic ImagingDiagnostic RadiologyUltrasonographyGynecologic ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMedical ImagingOvarian ImagingPolycystic Ovary SyndromeBland-altman PlotClarityComparative Diagnostic PerformanceFollicular Size MeasurementPolycystic Ovary Syndrome ImagingSpin Echo ImagingSubjective Noise EvaluationThree-dimensional Ovarian Imaging
Objective: To investigate the diagnostic performance of high-resolution single-shot fast spin-echo (SSFSE) imaging with deep learning (DL) reconstruction algorithm on follicle counting and compare it with original SSFSE images and conventional fast spin-echo (FSE) images. Methods: This study included 20 participants (40 ovaries) with clinically confirmed polycystic ovary syndrome (PCOS) who underwent high-resolution ovary MRI, including three-plane T2-weighted FSE sequences and slice-matched T2-weighted SSFSE sequences. A DL reconstruction algorithm was applied to the SSFSE sequences to generate SSFSE-DL images, and the original SSFSE images were also saved. Subjective evaluations such as the blurring artifacts, subjective noise, and clarity of the follicles on the SSFSE-DL, SSFSE, and conventional FSE images were independently conducted by two observers. Intra-class correlation coefficients and Bland–Altman plots were used to present the repeatability and reproducibility of the follicle number per ovary (FNPO) based on the three types of images. Results: SSFSE-DL images showed less blurring artifact, subjective noise, and better clarity of the follicles than SSFSE and FSE (p < 0.05). For the repeatability of the FNPO, SSFSE-DL showed the highest intra-observer (ICC = 0.930; 95% CI: 0.878–0.962) and inter-observer (ICC = 0.914; 95% CI: 0.843–0.953) agreements. The inter-observer 95% limits of agreement (LOA) for SSFSE-DL, SSFSE, and FSE ranged from −3.7 to 4.5, −4.4 to 7.0, and −7.1 to 7.6, respectively. The intra-observer 95% LOA for SSFSE-DL, SSFSE, and FSE ranged from −3.5 to 4.0, −5.1 to 6.1, and −5.7 to 4.2, respectively. The absolute values of intra-observer and inter-observer differences for SSFSE-DL were significantly lower than those for SSFSE and FSE (p < 0.05). Conclusions: Compared with the original SSFSE images and the conventional FSE images, high-resolution SSFSE images with DL reconstruction algorithm can better display follicles, thus improving FNPO assessment.
25
The Diagnosis of Polycystic Ovary Syndrome during Adolescence
Selma F. Witchel, Sharon E. Oberfield, Robert L. Rosenfield et al. · Hormone Research in Paediatrics · 2015 · 3.1K citations · Full text
Medicine, Endocrinology, Pediatrics +17
Ricardo Azziz, Enrico Carmina, Didier Dewailly et al. · The Journal of Clinical Endocrinology & Metabolism · 2006 · 2.1K citations · Full text
Medicine, Endocrinology, Gynecology +11