Synergistic Signal Amplification-Initiated Innovative Self-Powered Photoelectrochemical Aptasensing: An Ingenious Photocathode Activated by the High-Light-Harvesting Photoanode

Peilin Yang, Huihui Jiang, Hang Zhang, Xiuli Hou, Xin Gao, Qian Liu

Analytical Chemistry · 2023 · 54 citations · 39 references

DOIFull text

Open access

Concepts

TL;DR

High‑sensitivity self‑powered cathodic photoelectrochemical analysis can be achieved by combining innovative photoelectrodes with signal‑amplification strategies. This study develops a novel self‑powered PEC aptasensing platform that merges a synergistically amplified photocathode with a high‑light‑harvesting photoanode. The platform employs a dual‑photoelectrode system where nitrogen‑doped graphene enhances the BiOBr photocathode current, the Bi₂S₃‑C₃N₄ photoanode supplies high light harvesting, and an aptamer selectively captures streptomycin to generate amplified photocurrent. Under optimal conditions, the sensor exhibits a linear range of 1×10⁻¹¹ to 5×10⁻⁷ M, a detection limit of 1.18×10⁻¹² M, excellent stability and selectivity for streptomycin, and accurate performance in water samples.

Abstract

Exploiting ingenious photoelectrodes and innovative signal amplification strategies has the potential to achieve high sensitivity in self-powered cathodic photoelectrochemical (PEC) analysis. In this work, a novel self-powered PEC sensing platform was constructed by integrating a synergistic signal amplification of an ingenious photocathode with a high light-harvesting photoanode. In the dual photoelectrode-based PEC system, the amplified photocurrent signals were induced by a synergistic enhancement: (1) the photocurrent of the BiOBr photocathode was improved by the incorporation of nitrogen-doped graphene; (2) the photocurrent of the self-powered sensor was activated by the high-light-harvesting Bi2S3-C3N4 photoanode. Subsequently, the rational mechanism for synergistic signal amplification was investigated. For the construction of the sensing interface, an aptamer was introduced as the recognition element to specifically capture the streptomycin (STR) target. Under optimal conditions, the constructed self-powered aptasensor has the merits of good linear range (1 × 10-11 to 5 × 10-7 M), acceptable limit of detection (1.18 × 10-12 M), and excellent stability and selectivity for STR detection. Additionally, the proposed self-powered aptasensor showed acceptable accuracy for the detection of STR in water. Hopefully, this might stimulate more interest in designing and constructing novel platforms for exquisite photocathodic monitoring of various contaminants in the environment.

References

39