Frontiers in Endocrinology · 2023 · 47 citations · 17 references
MedicineEndocrinologyObstetricsDiabetologyGestational DiabetesMaternal-fetal MedicineBlood Glucose MonitoringContinuous Glucose MonitoringDiabetes MellitusGestational Diabetes MellitusGlycemic ControlGlycemic MonitoringBlood Glucose RegulationGestational Diabetes Glycemic ControlGestational Diabetes MonitoringGestational Weight Gain MeasurementGlucose MonitoringHemoglobin A1c TestingIntrapartum Glucose MonitoringPrenatal Glycemic Control
Objective This study evaluated the effect of continuous glucose monitoring (CGM) versus self-monitored blood glucose (SMGB) in gestational diabetes mellitus (GDM) with hemoglobin A1c (HbA1c) <6%. Methods From January 2019 to February 2021, 154 GDM patients with HbA1c<6% at 24–28 gestational weeks were recruited and assigned randomly to either SMBG only or CGM in addition to SMBG, with 77 participants in each group. CGM was used in combination with fingertip blood glucose monitoring every four weeks until antepartum in the CGM group, while in the SMBG group, fingertip blood glucose monitoring was applied. The CGM metrics were evaluated after 8 weeks, HbA1c levels before delivery, gestational weight gain (GWG), adverse pregnancy outcomes and CGM medical costs were compared between the two groups. Results Compared with patients in the SMBG group, the CGM group patients had similar times in range (TIRs) after 8 weeks (100.00% (93.75-100.00%) versus 99.14% (90.97-100.00%), p =0.183) and HbA1c levels before delivery (5.31 ± 0.06% versus 5.35 ± 0.06%, p =0.599). The proportion with GWG within recommendations was higher in the CGM group (59.7% versus 40.3%, p =0.046), and the newborn birth weight was lower (3123.79 ± 369.58 g versus 3291.56 ± 386.59 g, p =0.015). There were no significant differences in prenatal or obstetric outcomes, e.g., cesarean delivery rate, hypertensive disorders, preterm births, macrosomia, hyperbilirubinemia, neonatal hypoglycemia, respiratory distress, and neonatal intensive care unit admission >24 h, between the two groups. Considering glucose monitoring, SMBG group patients showed a lower cost than CGM group patients. Conclusions For GDM patients with HbA1c<6%, regular SMBG is a more economical blood glucose monitoring method and can achieve a similar performance in glycemic control as CGM, while CGM is beneficial for ideal GWG.
17
Barbara Daly, Konstantinos A. Toulis, G. Neil Thomas et al. · PLoS Medicine · 2018 · 337 citations · Full text
Fan Yu, Lijuan Lv, Zhijiang Liang et al. · The Journal of Clinical Endocrinology & Metabolism · 2014 · 153 citations · Full text
Louise Groth Grunnet, Susanne Hansen, Line Hjort et al. · Diabetes Care · 2017 · 126 citations · Full text