Environmental Science Processes & Impacts · 2023 · 28 citations · 47 references
Public HealthEnvironmental EngineeringEnvironmental SciencesAir PollutionEnvironmental HealthIndoor Environmental QualityAir Pollutant EmissionsAir PollutantsAir QualityIndoor Air PollutionIndoor Pollutant SourcesParticulate MatterCleaning Product EmissionsCooking EmissionsIndoor Air QualityIndoor Air Quality ImpactsIndoor Air Quality MeasurementIndoor Environmental InvestigationIndoor Environmental SmokePollutant Dispersion In Kitchens
during operating hours). During evening kitchen cleaning, we observed an increase in the signal of chlorinated gases from 1.1-9.0 times their values during daytime cooking. Particulate matter mass loadings tripled at these times. While exposure to cooking emissions in this indoor environment was reduced effectively by the high ventilation rate, exposure to particulate matter and chlorinated gases was elevated during evening cleaning periods. This emphasizes the need for careful consideration of ventilation rates and methods in commercial kitchen environments during all hours of kitchen operation.
47