EuroIntervention · 2023 · 49 citations · 17 references
MedicineCardiologySurgeryCardiothoracic SurgeryInterventional CardiologyCardiac CatheterizationCardiac Valve SurgerySurgical Valve ReplacementTranscatheter Aortic Valve ReplacementTranscatheter Valve TherapyValvular Heart Disease CareAnatomic FeasibilityCatheter-based Valve InterventionCoronary Flow AssessmentPre-procedural ImagingRedo Transcatheter Valve InterventionRedo Valve SurgeryValve Deployment TechniqueValves
BACKGROUND: Transcatheter aortic valve implantation in an existing transcatheter valve (redo-TAVI) pins the index valve leaflets in the open position (neoskirt), which can cause coronary flow compromise and limit access. Whether anatomy may preclude redo-TAVI in self-expanding Evolut valves is unknown. AIMS: We aimed to evaluate the anatomical feasibility of redo-TAVI by simulating implantation of a balloon-expandable SAPIEN 3 (S3) within an Evolut or an Evolut within an Evolut. METHODS: A total of 204 post-TAVI computed tomography (CT) scans from the Evolut Low Risk CT substudy were analysed. Five redo-TAVI positions were evaluated: S3-in-Evolut inflow-to-inflow, S3 outflow at Evolut nodes 4, 5, and 6, and Evolut-in-Evolut inflow-to-inflow. Univariable modelling identified pre-TAVI clinical characteristics, CT anatomical parameters, and procedural variables associated with coronary flow compromise using the neoskirt height and post-TAVI aortic root dimensions. RESULTS: The risk of coronary flow compromise was lowest when the S3 outflow was at Evolut node 4 (20%) and highest when at Evolut node 6 (75%). The highest likelihood of preserving coronary accessibility occurred with the S3 outflow at Evolut node 4. Female sex and higher body mass index were associated with a higher risk of coronary flow compromise, as were a smaller annulus diameter, lower sinus of Valsalva height and width, shorter coronary height, smaller sinotubular junction diameter, and shallower Evolut implant depth. CONCLUSIONS: The feasibility of redo-TAVI after Evolut failure is multifactorial and relates to the native annular anatomy, as well as the implantation depth of the index and second bioprostheses. Placement of an S3 at a lower Evolut position may reduce the risk of coronary flow compromise while preserving coronary access. CLINICALTRIALS: gov: NCT02701283.
17
Catherine M Otto, Rick A. Nishimura, Robert O. Bonow et al. · Circulation · 2020 · 2.4K citations · Full text
Medicine, Cardiology, Surgery +13
2021 ESC/EACTS Guidelines for the management of valvular heart disease
Alec Vahanian, Friedhelm Beyersdorf, Fabien Praz et al. · EuroIntervention · 2022 · 367 citations · Full text
Medicine, Cardiology, Surgery +17