Open Forum Infectious Diseases · 2023 · 12 citations · 13 references
Life SciencesInfectious DiseasesMicrobiologyAntimicrobial ResistanceBacteriologyMedical MicrobiologyAntibiotic ResistanceBacterial EpidemiologyBacterial InfectionsCarbapenem ResistanceDiagnostic BacteriologyHealthcare-associated Outbreak InvestigationBacterial Outbreak InvestigationCross-sectional Prevalence SurveysDisease Prevalence SurveysFacility-level Antimicrobial SurveillancePolymerase Chain Reaction DetectionPseudomonas Aeruginosa ResistancePseudomonas SpeciesTransmission Of Resistant Organisms
Abstract Background Contaminated healthcare facility wastewater plumbing is recognized as a source of carbapenemase-producing organism transmission. In August 2019, the Tennessee Department of Health (TDH) identified a patient colonized with Verona integron-encoded metallo-beta-lactamase-producing carbapenem-resistant Pseudomonas aeruginosa (VIM-CRPA). A record review revealed that 33% (4 of 12) of all reported patients in Tennessee with VIM had history of prior admission to acute care hospital (ACH) A intensive care unit (ICU) Room X, prompting further investigation. Methods A case was defined as polymerase chain reaction detection of blaVIM in a patient with prior admission to ACH A from November 2017 to November 2020. The TDH performed point prevalence surveys, discharge screening, onsite observations, and environmental testing at ACH A. The VIM-CRPA isolates underwent whole-genome sequencing (WGS). Results In a screening of 44% (n = 11) of 25 patients admitted to Room X between January and June 2020, we identified 36% (n = 4) colonized with VIM-CRPA, resulting in 8 cases associated with Room X from March 2018 to June 2020. No additional cases were identified in 2 point-prevalence surveys of the ACH A ICU. Samples from the bathroom and handwashing sink drains in Room X grew VIM-CRPA; all available case and environmental isolates were found to be ST253 harboring blaVIM-1 and to be closely related by WGS. Transmission ended after implementation of intensive water management and infection control interventions. Conclusions A single ICU room's contaminated drains were associated with 8 VIM-CRPA cases over a 2-year period. This outbreak highlights the need to include wastewater plumbing in hospital water management plans to mitigate the risk of transmission of antibiotic-resistant organisms to patients.
13
Valérie Decraene, Hang Phan, Ryan George et al. · Antimicrobial Agents and Chemotherapy · 2018 · 147 citations · Full text
Gaud Catho, Romain Martischang, Filippo Boroli et al. · Critical Care · 2021 · 112 citations · Full text
Paz Aranega-Bou, Ryan George, N.Q. Verlander et al. · Journal of Hospital Infection · 2018 · 82 citations · Full text