Journal of Cataract & Refractive Surgery · 2023 · 37 citations · 17 references
MedicineOphthalmologyVision ScienceAnterior SegmentClinical Vision ScienceRefractive SurgeryAxial ElongationCataract AssessmentLens ImagingOcular BiometryRefractive ErrorRefractive Error AssessmentAccuracyAxial Length Prediction ModelsBiometric FormulaeIol Power CalculationLens BiometryLens Power DeterminationOcular Component Contributions To Axial LengthPredictive Performance
PURPOSE: In short eyes, to compare the predictive accuracy of newer intraocular lens (IOL) power calculation formulas using traditional and segmented axial length (AL) measurements. SETTING: Cullen Eye Institute, Baylor College of Medicine, Houston, Texas and East Valley Ophthalmology, Mesa, Arizona. DESIGN: Multi-center retrospective case series. METHODS: Measurements from an optical biometer were collected in eyes with AL <22 mm. IOL power calculations were performed with 15 formulas using 2 AL values: (1) machine-reported traditional AL (Td-AL) and (2) segmented AL calculated with the Cooke-modified AL nomogram (CMAL). 1 AL method and 7 formulas were selected for pairwise analysis of mean absolute error (MAE) and root mean square absolute error (RMSAE). RESULTS: The study comprised 278 eyes. Compared with the Td-AL, the CMAL produced hyperopic shifts without differences in RMSAE. The ZEISS AI IOL Calculator (ZEISS AI), K6, Kane, Hill-RBF, Pearl-DGS, EVO, and Barrett Universal II (Barrett) formulas with Td-AL were compared pairwise. The ZEISS AI demonstrated smaller MAE and RMSAE than the Barrett, Pearl-DGS, and Kane. K6 had a smaller RMSAE than the Barrett formula. In 73 eyes with shallow anterior chamber depth, the ZEISS AI and Kane had a smaller RMSAE than the Barrett. CONCLUSIONS: ZEISS AI outperformed Barrett, Pearl-DGS, and Kane. The K6 formula outperformed some formulas in selected parameters. Across all formulas, use of a segmented AL did not improve refractive predictions.
17
Wolfgang Haigis, Barbara A.M. Lege, Naomi R. Miller et al. · Graefe s Archive for Clinical and Experimental Ophthalmology · 2000 · 765 citations
Sources of error in intraocular lens power calculation
Sverker Norrby · Journal of Cataract & Refractive Surgery · 2008 · 656 citations
Medicine, Ophthalmology, Surgery +17
Accuracy of Intraocular Lens Calculation Formulas
Ronald B. Melles, Jack T. Holladay, William J. Chang · Ophthalmology · 2017 · 644 citations · Full text
Avery H. Weiss · Archives of Ophthalmology · 1989 · 171 citations