Journal of Prosthodontics · 2023 · 10 citations · 34 references
DentistryImplant DentistryMaxillofacial SurgeryDentoalveolar SurgeryDigital Implant DentistryImplant SurgeryDigital Impression TechniquesImplant Impression TechniquesConventional Implant ImpressionConventional Impression AccuracyEdentulous Arch ScanningEdentulous Digital ImpressionsImplant Angulation EffectsImplant Impression ScanningModel Fabrication AccuracyScan Body Accuracy
PURPOSE: To compare the accuracy of digitizing conventional impressions to intraoral surface scans for all-on-four treatment in the maxillary arch. MATERIALS AND METHODS: An edentulous maxillary arch model with four implants placed in an all-on-four design was fabricated. Intraoral surface scans (n = 10) were obtained using an intraoral scanner after scan body insertion. For conventional polyvinylsiloxane impressions of the model, implant copings were inserted into the implant fixation for implant level, opened tray impressions (n = 10). The model and conventional impressions were digitized to obtain digital files. A reference file was created using a laboratory-scanned conventional standard tessellation language (STL) file with analog to scan the body using exocad software. STL datasets from the two digital and conventional impression groups were superimposed with reference files to assess the 3D deviations. Two-way ANOVA and paired-samples t-test was performed to assess the difference in trueness and examine the effects of impression technique and implant angulation on the deviation amount. RESULTS: No significant differences were found between the conventional impression and intraoral surface scan groups F(1, 76) = 2.705, p = 0.104. No significant differences were found between conventional straight and digital straight implants and between conventional and digital tilted implants F(1, 76) = .041, p = 0.841. No significant differences were found between conventional straight and conventional tilted implants p = 0.07 and between digital straight and digital tilted implants p = 0.08. CONCLUSION: Digital scans were more accurate than conventional impressions. The digital straight implants were more accurate than the conventional straight implants, and the digital tilted implants were more accurate than the conventional tilted implants, with higher accuracy for digital straight implants.
34
Paulo Maló, Bo Rangert, Miguel de Araújo Nobre · Clinical Implant Dentistry and Related Research · 2003 · 763 citations
Accuracy of full-arch scans using intraoral scanners
Sebastian B. M. Patzelt, Archontia Emmanouilidi, Susanne Stampf et al. · Clinical Oral Investigations · 2013 · 447 citations
Dentistry, Oral Radiology, Radiology +13
Frank S. Andriessen, David R Rijkens, Wicher J. van der Meer et al. · Journal of Prosthetic Dentistry · 2013 · 316 citations · Full text