Biomedical Signal Processing and Control · 2023 · 15 citations · 29 references
EngineeringBiomedical EngineeringCardiologyBiomedical Signal ProcessingElectrophysiologyHealthcare Quality ImprovementBiomedical Signal ModelingCardiac Signal ProcessingElectrocardiogram AnalysisElectrocardiogram InterpretationElectrocardiography12-Lead ElectrocardiographyEcg Quality AssessmentEcg Signal DenoisingEcg Signal PreprocessingElectrocardiogram DenoisingEnsemble Learning TheoryLow-frequency NoiseSignal Quality Assessment
In a 12-lead electrocardiogram (ECG) examination, the ECG signals often have low-quality data problems due to high-frequency noise caused by muscles and low-frequency noise caused by body movement, breathing. These problems cause delays in examination results and increase medical costs. For this reason, solving low-quality data and missing ECG data problems can provide patients with improved medical services, reducing the work-loss and medical costs. The purpose of this study is to develop a signal restoration model for each of the 12 signals to solve the low-quality and missing data problems caused by mechanical and operator errors during 12-lead ECG examinations. For this study, 13,862 high-quality 12-lead ECG recordings for multiple diseases were obtained from the 12-lead ECG database of a general hospital from 2016 to 2020. Two strategies were adopted to develop an accurate restoration model. First, to obtain the optimal input parameters for the ECG regeneration model for each ECG signal, linear regression (LR) models were developed for all 165 three-signal combinations of 11 signals. Second, the restoration models were constructed in a parallel architecture combining bidirectional long short-term memory (Bi-LSTM) with a convolutional neural network (CNN) to learn the temporal and spatial features of optimal combinations. The performances of the 165 candidate combinations for restoring missing signal were analyzed through the LR model to find the optimal input parameter for all ECG signals. The average root mean square error of the optimal combinations was 0.082 μV. The average RMSE of the signal restoration model made using the optimal combinations and deep-learning model (Bi-LSTM&CNN) was 0.037 μV, and the cosine simplicity was 0.991. This ECG restoration technology obtained optimal input parameters through the LR model and developed ECG restoration model through the Bi-LSTM&CNN combined model to restore ECG signals for multiple diseases. The 12-lead ECG signal restoration model developed through this study offers high accuracy for the magnitude and direction components of all 12 signals. This technology can be used in emergency medical systems and remote ECG measurement situations, as well as in synthetic ECG generation technologies for constructing research datasets.
29
Qingsong Xu, Yi‐Zeng Liang · Chemometrics and Intelligent Laboratory Systems · 2001 · 1.1K citations
Learning to Monitor Machine Health with Convolutional Bi-Directional LSTM Networks
Rui Zhao, Ruqiang Yan, Jinjiang Wang et al. · Sensors · 2017 · 734 citations · Full text
Baseline correction using asymmetrically reweighted penalized least squares smoothing
Sung‐June Baek, Aaron Park, Young‐Jin Ahn et al. · The Analyst · 2014 · 454 citations