Computerized Medical Imaging and Graphics · 2023 · 17 citations · 37 references
Veterinary MedicineOphthalmologyVision ScienceBiomedical ImagingDiagnostic ImagingOcular ImagingImage QuantificationMedical Image AnalysisMedical ImagingOphthalmic ImagingOptical Coherence TomographyRetinal ImagingAutomatic SegmentationBlood FlowContrast EnhancementLocal Contrast EnhancementLocal EnhancementNon-invasive Imaging AssessmentOptical Coherence Tomography AngiographyThresholding
Optical coherence tomography angiography (OCTA) is a non-invasive ophthalmic imaging modality that is widely used in clinical practice. Recent technological advances in OCTA allow imaging of blood flow deeper than the retinal layers, at the level of the choriocapillaris (CC), where a granular image is obtained showing a pattern of bright areas, representing blood flow, and a pattern of small dark regions, called flow voids (FVs). Several clinical studies have reported a close correlation between abnormal FVs distribution and multiple diseases, so quantifying changes in FVs distribution in CC has become an area of interest for many clinicians. However, CC OCTA images present very complex features that make it difficult to correctly compare FVs during the monitoring of a patient. In this work, we propose fully automatic approaches for the segmentation and monitoring of FVs in CC OCTA images. First, a baseline approach, in which a fully automatic segmentation methodology based on local contrast enhancement and global thresholding is proposed to segment FVs and measure changes in their distribution in a straightforward manner. Second, a robust approach in which, prior to the use of our segmentation methodology, an unsupervised trained neural network is used to perform a deformable registration that aligns inconsistencies between images acquired at different time instants. The proposed approaches were tested with CC OCTA images collected during a clinical study on the response to photodynamic therapy in patients affected by chronic central serous chorioretinopathy (CSC), demonstrating their clinical utility. The results showed that both approaches are accurate and robust, surpassing the state of the art, therefore improving the efficacy of FVs as a biomarker to monitor the patient treatments. This gives great potential for the clinical use of our methods, with the possibility of extending their use to other pathologies or treatments associated with this type of imaging.
37
Fiji: an open-source platform for biological-image analysis
Johannes Schindelin, Ignacio Arganda‐Carreras, Erwin Frise et al. · Nature Methods · 2012 · 70.9K citations
Image quality assessment: from error visibility to structural similarity
Zhou Wang, Alan C. Bovik, Hamid R. Sheikh et al. · IEEE Transactions on Image Processing · 2004 · 56K citations
Delving Deep into Rectifiers: Surpassing Human-Level Performance on ImageNet Classification
Kaiming He, Xiangyu Zhang, Shaoqing Ren et al. · 2015 · 18.8K citations
Multiscale structural similarity for image quality assessment
Zhou Wang, Eero P. Simoncelli, Alan C. Bovik · 2004 · 5.9K citations