Eye and Vision · 2023 · 33 citations · 36 references
MedicineOphthalmologyVision ScienceAnterior SegmentOcular ImagingOphthalmic SurgeryCorneal AnatomyCorneal ImagingCorneal TopographyOcular BiometryOcular UltrasonographyOphthalmic ImagingAstigmatismCentral Corneal Thickness MeasurementCorneal Astigmatism AnalysisCorneal Astigmatism AssessmentCorneal DiameterCorneal Thickness AssessmentCorneal Topography AssessmentKeratometry By Ultrasound
Abstract Purpose To systematically compare and rank ocular measurements with optical and ultrasound biometers based on big data. Methods PubMed, Embase, the Cochrane Library and the US trial registry ( www.ClinicalTrial.gov ) were used to systematically search trials published up to October 22nd, 2020. We included comparative studies reporting the following parameters measured by at least two devices: axial length (AL), flattest meridian keratometry (Kf), steepest meridian keratometry (Ks), mean keratometry (Km), astigmatism (AST), astigmatism vectors J 0 and J 45 , anterior chamber depth (ACD), aqueous depth (AQD), central corneal thickness (CCT), corneal diameter (CD) and lens thickness (LT). A network-based big data analysis was conducted using STATA version 13.1. Results Across 129 studies involving 17,181 eyes, 12 optical biometers and two ultrasound biometers (with both contact and immersion techniques) were identified. A network meta-analysis for AL and ACD measurements found that statistically significant differences existed when contact ultrasound biometry was compared with the optical biometers. There were no statistically significant differences among the four swept-source optical coherence tomography (SS-OCT) based devices (IOLMaster 700, OA-2000, Argos and ANTERION). As for Ks, Km and CD, statistically significant differences were found when the Pentacam AXL was compared with the IOLMaster and IOLMaster 500. There were statistically significant differences for CCT when the OA-2000 was compared to Pentacam AXL, IOLMaster 700, Lenstar, AL-Scan and Galilei G6. Conclusion For AL and ACD, contact ultrasound biometry obtains the lower values compared with optical biometers. The Pentacam AXL achieves the lowest values for keratometry and CD. The smallest value for CCT measurement is found with the OA-2000.
36
Bias in meta-analysis detected by a simple, graphical test
Matthias Egger, George Davey Smith, Martin Schneider et al. · BMJ · 1997 · 56.3K citations
Brian Hutton, Georgia Salanti, Deborah M Caldwell et al. · Annals of Internal Medicine · 2015 · 8.1K citations
Checking consistency in mixed treatment comparison meta‐analysis
Sofia Dias, Nicky J. Welton, Deborah M Caldwell et al. · Statistics in Medicine · 2010 · 2.5K citations
Automating network meta‐analysis
Gert van Valkenhoef, Guobing Lu, Bert de Brock et al. · Research Synthesis Methods · 2012 · 800 citations