Pediatric Blood & Cancer · 2023 · 18 citations · 24 references
MedicineOncologyRadiation OncologyCentral Nervous System Radiation OncologyPediatric RadiologyTreatment PlanningComputed TomographyCraniospinal IrradiationPediatric Central Nervous System RadiotherapyPediatric Neuro-oncologyPediatric Radiation OncologyRadiation Treatment PlanningAutomated Treatment PlanningImaging-based Treatment PlanningMedulloblastoma IrradiationPediatric Cranial IrradiationPediatric Craniospinal IrradiationPediatric Radiation Therapy PlanningPhoton Craniospinal IrradiationThree-dimensional Conformal Radiation Therapy Planning
PURPOSE: Pediatric patients with medulloblastoma in low- and middle-income countries (LMICs) are most treated with 3D-conformal photon craniospinal irradiation (CSI), a time-consuming, complex treatment to plan, especially in resource-constrained settings. Therefore, we developed and tested a 3D-conformal CSI autoplanning tool for varying patient lengths. METHODS AND MATERIALS: Autocontours were generated with a deep learning model trained:tested (80:20 ratio) on 143 pediatric medulloblastoma CT scans (patient ages: 2-19 years, median = 7 years). Using the verified autocontours, the autoplanning tool generated two lateral brain fields matched to a single spine field, an extended single spine field, or two matched spine fields. Additional spine subfields were added to optimize the corresponding dose distribution. Feathering was implemented (yielding nine to 12 fields) to give a composite plan. Each planning approach was tested on six patients (ages 3-10 years). A pediatric radiation oncologist assessed clinical acceptability of each autoplan. RESULTS: The autocontoured structures' average Dice similarity coefficient ranged from .65 to .98. The average V95 for the brain/spinal canal for single, extended, and multi-field spine configurations was 99.9% ± 0.06%/99.9% ± 0.10%, 99.9% ± 0.07%/99.4% ± 0.30%, and 99.9% ± 0.06%/99.4% ± 0.40%, respectively. The average maximum dose across all field configurations to the brainstem, eyes (L/R), lenses (L/R), and spinal cord were 23.7 ± 0.08, 24.1 ± 0.28, 13.3 ± 5.27, and 25.5 ± 0.34 Gy, respectively (prescription = 23.4 Gy/13 fractions). Of the 18 plans tested, all were scored as clinically acceptable as-is or clinically acceptable with minor, time-efficient edits preferred or required. No plans were scored as clinically unacceptable. CONCLUSION: The autoplanning tool successfully generated pediatric CSI plans for varying patient lengths in 3.50 ± 0.4 minutes on average, indicating potential for an efficient planning aid in a resource-constrained settings.
24
Birgitta Lannering, Stefan Rutkowski, François Doz et al. · Journal of Clinical Oncology · 2012 · 329 citations · Full text
Niloy R. Datta, Massoud Samiei, Stephan Bodis · International Journal of Radiation Oncology*Biology*Physics · 2014 · 232 citations · Full text
Automatic detection of contouring errors using convolutional neural networks
Dong Joo Rhee, Carlos Cárdenas, Hesham Elhalawani et al. · Medical Physics · 2019 · 102 citations · Full text
Medicine, Radiology, Computer Vision +15