IEEE Transactions on Power Electronics · 2022 · 72 citations · 26 references
EngineeringElectrical EngineeringCircuit TheoryMicroelectronicsPower ElectronicsAc-dc ConvertersConverter TopologiesDc-dc ConversionDc-dc ConvertersPower Electronics For Renewable EnergySnubber CircuitsConverter Topology DesignDc-dc Converter TopologiesHigh-efficiency ConverterPower DensityPower Density EnhancementSnubber Circuit DesignSwitching Loss ReductionTopology Design
Medium-voltage large-capacity dc transformer (DCT) is the key energy conversion link for building intelligent distribution grid. Increasing the voltage and capacity of single module in DCT can effectively improve the power density and reduce the system cost. Aiming at the integrated gate commutated thyristor (IGCT)-based high-capacity dc transformer (IGCT–HDCT), the asymmetric topology design and quasi-zero-loss switching composite modulation are proposed to achieve the construction of high efficiency and power density DCT. Through designing the snubber circuit and phase-shift ratio trajectory ingeniously, the zero-voltage switching- <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> and zero-current switching- <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">off</small> operation of the IGCT–HDCT can be maintained, which greatly reduces the switching loss and gives full play to the extremely low <sc xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">on</small> -state loss characteristics of IGCT. Meanwhile, the full-range soft-switching operation (from no-load to full-load) can be achieved in the composite modulation without adding any auxiliary component. And the design of the snubber circuit is greatly simplified, which cannot only effectively limit the <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dv</i> / <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dt</i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">di</i> / <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">dt</i> of power semiconductors, but also improves the power density and operating efficiency of IGCT–HDCT. Finally, the theoretical analysis of the proposed system solution is verified by building a 1.25 MW IGCT–HDCT engineering prototype, and the maximum operating efficiency reaches 98.6%–99.1%.
26
Stefan P. Engel, Marco Stieneker, Nils Soltau et al. · IEEE Transactions on Power Electronics · 2014 · 435 citations
Overview of DC–DC Converters Dedicated to HVdc Grids
Juan David Páez, David Frey, José Maneiro et al. · IEEE Transactions on Power Delivery · 2018 · 259 citations
Biao Zhao, Qiang Song, Wenhua Liu et al. · IEEE Transactions on Power Electronics · 2013 · 175 citations