Analysis identifying minimal governing parameters for clinically accurate in silico fractional flow reserve

Cyrus Tanade, S. James Chen, Jane A. Leopold, Amanda Randles

Frontiers in Medical Technology · 2022 · 12 citations · 66 references

DOIFull text

Open access

Concepts

Abstract

Background Personalized hemodynamic models can accurately compute fractional flow reserve (FFR) from coronary angiograms and clinical measurements (FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM1"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> ), but obtaining patient-specific data could be challenging and sometimes not feasible. Understanding which measurements need to be patient-tuned vs. patient-generalized would inform models with minimal inputs that could expedite data collection and simulation pipelines. Aims To determine the minimum set of patient-specific inputs to compute FFR using invasive measurement of FFR (FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM2"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">invasive</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> ) as gold standard. Materials and Methods Personalized coronary geometries ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM3"><mml:mi>N</mml:mi><mml:mo>=</mml:mo><mml:mn>50</mml:mn></mml:math> ) were derived from patient coronary angiograms. A computational fluid dynamics framework, FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM4"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> , was parameterized with patient-specific inputs: coronary geometry, stenosis geometry, mean arterial pressure, cardiac output, heart rate, hematocrit, and distal pressure location. FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM5"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> was validated against FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM6"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">invasive</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> and used as the baseline to elucidate the impact of uncertainty on personalized inputs through global uncertainty analysis. FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM7"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">streamlined</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> was created by only incorporating the most sensitive inputs and FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM8"><mml:msub><mml:mi/><mml:mrow><mml:mtext>semi-streamlined</mml:mtext></mml:mrow></mml:msub></mml:math> additionally included patient-specific distal location. Results FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM9"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> was validated against FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM10"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">invasive</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> via correlation ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM11"><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.714</mml:mn></mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM12"><mml:mi>p</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:math> ), agreement (mean difference: <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM13"><mml:mn>0.01</mml:mn><mml:mo>±</mml:mo><mml:mn>0.09</mml:mn></mml:math> ), and diagnostic performance (sensitivity: 89.5%, specificity: 93.6%, PPV: 89.5%, NPV: 93.6%, AUC: 0.95). FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM14"><mml:msub><mml:mi/><mml:mrow><mml:mtext>semi-streamlined</mml:mtext></mml:mrow></mml:msub></mml:math> provided identical diagnostic performance with FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM15"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> . Compared to FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM16"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">baseline</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> vs. FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM17"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">invasive</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> , FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM18"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">streamlined</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> vs. FFR <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM19"><mml:msub><mml:mi/><mml:mrow><mml:mrow><mml:mi mathvariant="normal">invasive</mml:mi></mml:mrow></mml:mrow></mml:msub></mml:math> had decreased correlation ( <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM20"><mml:mi>r</mml:mi><mml:mo>=</mml:mo><mml:mn>0.64</mml:mn></mml:math> , <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM21"><mml:mi>p</mml:mi><mml:mo>&lt;</mml:mo><mml:mn>0.001</mml:mn></mml:math> ), improved agreement (mean difference: <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML" id="IM22"><mml:mn>0.01</mml:mn><mml:mo>±</mml:mo><mml:mn>0.08</mml:mn></mml:math> ), and comparable diagnostic performance (sensitivity: 79.0%, specificity: 90.3%, PPV: 83.3%, NPV: 87.5%, AUC: 0.90). Conclusion Streamlined models could match the diagnostic performance of the baseline with a full gamut of patient-specific measurements. Capturing coronary hemodynamics depended most on accurate geometry reconstruction and cardiac output measurement.

References

66