Publication | Open Access
Ultrasound-Guided Infraclavicular Axillary Vein Versus Internal Jugular Vein Cannulation in Critically Ill Mechanically Ventilated Patients: A Randomized Trial
18
Citations
12
References
2022
Year
No difference was found between the real-time ultrasound-guided out-of-plane cannulation of the IJV and the infraclavicular real-time ultrasound-guided in-plane cannulation of the AXV. Both techniques are equally efficient and safe in mechanically ventilated critically ill patients.