IEEE Journal of Translational Engineering in Health and Medicine · 2022 · 38 citations · 37 references
MedicineBiomedical EngineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast Cancer ImagingBreast ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingBreast Lesion DiagnosisT1 ContrastT1-weighted Imaging
OBJECTIVE: Breast dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is a sensitive imaging technique critical for breast cancer diagnosis. However, the administration of contrast agents poses a potential risk. This can be avoided if contrast-enhanced MRI can be obtained without using contrast agents. Thus, we aimed to generate T1-weighted contrast-enhanced MRI (ceT1) images from pre-contrast T1 weighted MRI (preT1) images in the breast. METHODS: We proposed a generative adversarial network to synthesize ceT1 from preT1 breast images that adopted a local discriminator and segmentation task network to focus specifically on the tumor region in addition to the whole breast. The segmentation network performed a related task of segmentation of the tumor region, which allowed important tumor-related information to be enhanced. In addition, edge maps were included to provide explicit shape and structural information. Our approach was evaluated and compared with other methods in the local (n = 306) and external validation (n = 140) cohorts. Four evaluation metrics of normalized mean squared error (NRMSE), Pearson cross-correlation coefficients (CC), peak signal-to-noise ratio (PSNR), and structural similarity index map (SSIM) for the whole breast and tumor region were measured. An ablation study was performed to evaluate the incremental benefits of various components in our approach. RESULTS: Our approach performed the best with an NRMSE 25.65, PSNR 54.80 dB, SSIM 0.91, and CC 0.88 on average, in the local test set. CONCLUSION: Performance gains were replicated in the validation cohort. SIGNIFICANCE: We hope that our method will help patients avoid potentially harmful contrast agents. Clinical and Translational Impact Statement-Contrast agents are necessary to obtain DCE-MRI which is essential in breast cancer diagnosis. However, administration of contrast agents may cause side effects such as nephrogenic systemic fibrosis and risk of toxic residue deposits. Our approach can generate DCE-MRI without contrast agents using a generative deep neural network. Thus, our approach could help patients avoid potentially harmful contrast agents resulting in an improved diagnosis and treatment workflow for breast cancer.
37
Deep Residual Learning for Image Recognition
Kaiming He, Xiangyu Zhang, Shaoqing Ren et al. · 2016 · 222.1K citations · Full text
Generative adversarial networks
Ian Goodfellow, Jean Pouget-Abadie, Mehdi Mirza et al. · Communications of the ACM · 2020 · 13.6K citations · Full text
TransUNet: Transformers Make Strong Encoders for Medical Image Segmentation
Jieneng Chen, Yongyi Lu, Qihang Yu et al. · arXiv (Cornell University) · 2021 · 3.8K citations · Full text
Spectral Normalization for Generative Adversarial Networks
Takeru Miyato, Toshiki Kataoka, Masanori Koyama et al. · arXiv (Cornell University) · 2018 · 2.3K citations · Full text