Alzheimer s Research & Therapy · 2022 · 33 citations · 39 references
EngineeringBioengineeringBiomedical EngineeringBiomedical Signal ProcessingElectrophysiologyNeural EngineeringElectrode PlacementElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyChannel ConfigurationElectrode Configuration DesignElectroencephalogram ClassificationElectroencephalographic DiagnosisMild Cognitive Impairment DiagnosisSupport Vector ClassificationWearable DevicesWearable Technology
BACKGROUND: Early diagnosis of mild cognitive impairment (MCI) is essential for timely treatment planning. With recent advances in the wearable technology, interest has increasingly shifted toward computer-aided self-diagnosis of MCI using wearable electroencephalography (EEG) devices in daily life. However, no study so far has investigated the optimal electrode configurations for the efficient diagnosis of MCI while considering the design factors of wearable EEG devices. In this study, we aimed to determine the optimal channel configurations of wearable EEG devices for the computer-aided diagnosis of MCI. METHOD: We employed an EEG dataset collected from 21 patients with MCI and 21 healthy control subjects. After evaluating the classification accuracies for all possible electrode configurations for the two-, four-, six-, and eight-electrode conditions using a support vector machine, the optimal electrode configurations that provide the highest diagnostic accuracy were suggested for each electrode condition. RESULTS: The highest classification accuracies of 74.04% ± 4.82, 82.43% ± 6.14, 86.28% ± 2.81, and 86.85% ± 4.97 were achieved for the optimal two-, four-, six-, and eight-electrode configurations, respectively, which demonstrated the possibility of precise machine-learning-based diagnosis of MCI with a limited number of EEG electrodes. Additionally, further simulations with the EEG dataset revealed that the optimal electrode configurations had significantly higher classification accuracies than commercial EEG devices with the same number of electrodes, which suggested the importance of electrode configuration optimization for wearable EEG devices based on clinical EEG datasets. CONCLUSIONS: This study highlighted that the optimization of the electrode configuration, assuming the wearable EEG devices can potentially be utilized for daily life monitoring of MCI, is necessary to enhance the performance and portability.
39
A Mathematical Theory of Communication
Claude E. Shannon · Bell System Technical Journal · 1948 · 80.7K citations
Multiple significance tests: the Bonferroni method
Martin Bland, Doug Altman · BMJ · 1995 · 3.9K citations · Full text
Medicine, Immunology, Oncology +17
The Chi-square test of independence
Mary L. McHugh · Biochemia Medica · 2013 · 2.7K citations · Full text