Pediatrics & Neonatology · 2022 · 13 citations · 15 references
MedicineChild HealthPediatricsInfant HealthNeonatologyPreterm BirthCare Of Premature InfantsNeonatal Intensive CareNeonatal OutcomesNeonatal VentilationPreterm Infant CareRespiratory Distress In NewbornsFailed ExtubationLow Apgar ScoreMechanical Ventilation In NewbornsNeonatal Apgar ScoresNeonatal ExtubationNeonatal Mechanical VentilationNeonatal Outcomes AssessmentPreterm Infant Respiratory Failure
BackgroundMechanical ventilation is the primary treatment for preterm infants with respiratory failure. Prolonged intubation may lead to complications; thus, early extubation is desirable. No standard criteria exist for determining the appropriateness of extubating very-low-birth-weight (VLBW) infants. This study explored the predictors of successful extubation in preterm VLBW infants.MethodsThis retrospective cohort study included 60 preterm VLBW infants who underwent their first extubation in the neonatal intensive care unit in a regional hospital in Hsinchu, Taiwan, between January 2017 and November 2020. Successful extubation was defined as having no requirement of reintubation within 3 days of extubation. Potentially predictive variables, including demographics, prenatal characteristics, and ventilator parameters were compared between a successful extubation group and failed extubation group.ResultsOf the 60 infants, 47 (78.33%) underwent successful extubation. The successful extubation group had higher Apgar scores at 1 (7 vs. 6, P = 0.02) and 5 min (9 vs. 7, P = 0.007) than those of the failed extubation group. Ventilator inspiratory pressure and mean airway pressure were significantly lower at 24, 16, 8, and 1 h before extubation and upon its completion in the successful extubation group. The areas under a number of the receiver operating characteristic curve curves in this study were moderate, specifically, 0.72, 0.74, and 0.69. Statistical analysis revealed an association between ventilator parameters before 1 h extubation (IP > 17.5cmH2O, MAP >7.5 cmH2O, RSS >1.82) and extubation failure (odds ratio 1.73, 2.27, 2.46 and 95% confidence interval:1.16–2.6, 1.26–4.08, 1.06–5.68, respectively).ConclusionHigher Apgar scores at birth, lower ventilator inspiratory pressure, and mean airway pressure 24, 16, 8, and 1 h and 1 h RSS prior to extubation are associated with successful extubation in VLBW preterm infants. Mechanical ventilation is the primary treatment for preterm infants with respiratory failure. Prolonged intubation may lead to complications; thus, early extubation is desirable. No standard criteria exist for determining the appropriateness of extubating very-low-birth-weight (VLBW) infants. This study explored the predictors of successful extubation in preterm VLBW infants. This retrospective cohort study included 60 preterm VLBW infants who underwent their first extubation in the neonatal intensive care unit in a regional hospital in Hsinchu, Taiwan, between January 2017 and November 2020. Successful extubation was defined as having no requirement of reintubation within 3 days of extubation. Potentially predictive variables, including demographics, prenatal characteristics, and ventilator parameters were compared between a successful extubation group and failed extubation group. Of the 60 infants, 47 (78.33%) underwent successful extubation. The successful extubation group had higher Apgar scores at 1 (7 vs. 6, P = 0.02) and 5 min (9 vs. 7, P = 0.007) than those of the failed extubation group. Ventilator inspiratory pressure and mean airway pressure were significantly lower at 24, 16, 8, and 1 h before extubation and upon its completion in the successful extubation group. The areas under a number of the receiver operating characteristic curve curves in this study were moderate, specifically, 0.72, 0.74, and 0.69. Statistical analysis revealed an association between ventilator parameters before 1 h extubation (IP > 17.5cmH2O, MAP >7.5 cmH2O, RSS >1.82) and extubation failure (odds ratio 1.73, 2.27, 2.46 and 95% confidence interval:1.16–2.6, 1.26–4.08, 1.06–5.68, respectively). Higher Apgar scores at birth, lower ventilator inspiratory pressure, and mean airway pressure 24, 16, 8, and 1 h and 1 h RSS prior to extubation are associated with successful extubation in VLBW preterm infants.
15
Caffeine Therapy for Apnea of Prematurity
Barbara Schmidt, Robin S. Roberts, Peter G. Davis et al. · New England Journal of Medicine · 2006 · 1.2K citations · Full text
Chorioamnionitis and Culture-Confirmed, Early-Onset Neonatal Infections
Jonathan M. Wortham, Nellie I. Hansen, Stephanie J. Schrag et al. · PEDIATRICS · 2015 · 175 citations