Natural SciencesEarth SciencesMeteorologyAtmospheric ScienceClimatologyRemote SensingAtmospheric Sounding From SatellitesCalibrationLand Surface MonitoringSatellite Data CalibrationSatellite Data ValidationSatellite SensorsCalibration Of Satellite ProductsGlobal Navigation Satellite System NetworksPrecipitable WaterRegional Climate ChangeSatellite ValidationValidation Of Satellite ProductsWater Vapor ProfilingWater Vapor Validation
Although ground-based precipitable water vapor (PWV) can be obtained with a high temporal resolution and spatial resolution of tens of kilometers in an urban area using Global Navigation Satellite System (GNSS) observation, it remains fairly sparse in the vast regions over Mainland China. Satellite-derived PWV has a high spatial resolution, thereby enabling the accurate investigation of regional climate change. However, understanding the quality of satellite-derived PWV products is a prerequisite before use, which has become the focus of this study. PWV products, namely, MOD05_L2 and MYD05_L2, over the entirety of Mainland China derived from MODerate Resolution Imaging Spectroradiometer (MODIS) onboard Terra and Aqua satellites are validated over the period 2000–2017 using multiple sources, including GNSS, radiosonde, AErosol RObotic NETwork (AERONET), and European Center for Medium-Range Weather Forecasts ERA-Interim (ECMWF). The accuracy of MODIS PWV products is less than 4.3 mm over the entirety of Mainland China; however, it varies in four areas of South China (SC), North China (NC), Northwest China (NWC), and Tibetan Plateau (TP), separately with values ranging from 3 mm to 6 mm. A linear fit model is applied to calibrate the MODIS PWV products, and the accuracies of the corrected PWV from MODIS infrared (IR) and near-infrared (NIR) products have been improved by approximately 7.5% and 50.6%, respectively. The MODIS PWV is compared and calibrated in the four areas, and the improved accuracies vary widely. The root mean square error (RMSE) of IR PWV is approximately less than 4 mm over China except for the SC area with a value of approximately 5.3 mm after calibration, whereas the values of NIR PWV are approximately 2 mm over the entirety of Mainland China, except for the TP area, with a value of approximately 2.6 mm. The MODIS NIR PWV performs better than that of IR PWV data in most areas of Mainland China regardless of whether with calibration. The validation and calibration of MODIS water vapor products over Mainland China also indicate their capability to investigate the seasonal and annual variations as well as long-term trend changes in water vapor in China.
53
AERONET—A Federated Instrument Network and Data Archive for Aerosol Characterization
B. N. Holben, T. F. Eck, I. Slutsker et al. · Remote Sensing of Environment · 1998 · 8.5K citations · Full text
Satellite-derived land surface temperature: Current status and perspectives
Zhao-Liang Li, Bo‐Hui Tang, Hua Wu et al. · Remote Sensing of Environment · 2013 · 2.2K citations · Full text
Michael D. King, Yoram J. Kaufman, W. Paul Menzel et al. · IEEE Transactions on Geoscience and Remote Sensing · 1992 · 1.1K citations