7α-Biotinylated testosterone derivatives as tracers for a competitive chemiluminescence immunoassay of testosterone in serum

Peter B. Luppa, Christine Brückner, Ingrid Schwab, Sabine Hauck, Stefan Schmidmayr, Christian Birkmayer, Birgit Paulus, Hagen Hauptmann

Clinical Chemistry · 1997 · 22 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Abstract Ring core-biotinylated testosterone tracers were synthesized with bridges of three different lengths connecting the biotin moiety to the steroid core (7α-Cn-Bio-T, n = 3, 6, or 11). Together with a position 7-specific polyclonal anti-testosterone antibody, we used the 7α-C11-Bio-T tracer to develop a novel, labeled-hapten competitive immunoassay for total testosterone in serum. (The C3 and C6 tracers proved to be not suitable for analogous immunoassays.) Enhanced chemiluminescence signal was generated by use of a second immobilized antibody and a streptavidin–horseradish peroxidase conjugate. The measuring range of the assay is 0.2–20.0 nmol/L, linearity of serial dilutions can be demonstrated, the lower detection limit is 0.125 nmol/L, and the interassay imprecisions are 13–16%. Accuracy determinations in mass spectrometry-controlled reference specimens showed a mean recovery of 95%. In addition, the assay shows low cross-reactivities, demonstrating the favorable specificity of the combination of a “nearly native” tracer with a position analog antibody. The optimized steric structure and the long spacer arm of the biotinylated testosterone tracer make this chemiluminescence assay well-suited for measuring total testosterone concentration in serum.