Journal of Nuclear Medicine · 2022 · 59 citations · 18 references
MedicineNuclear MedicineRadiologyCardiac Nuclear MedicineDiagnostic ImagingDiagnostic Nuclear MedicineAttenuation CorrectionCardiac ImagingCardiac Nuclear ImagingDeep LearningMedical ImagingMyocardial Perfusion ImagingAttenuation Correction SystemsCardiac Myocardial Perfusion ImagingDeep Learning In RadiologyGenerative Adversarial NetworksMisregistration CorrectionNonuniform Attenuation CorrectionSpect Attenuation Correction
To improve diagnostic accuracy, myocardial perfusion imaging (MPI) SPECT studies can use CT-based attenuation correction (AC). However, CT-based AC is not available for most SPECT systems in clinical use, increases radiation exposure, and is impacted by misregistration. We developed and externally validated a deep-learning model to generate simulated AC images directly from non-AC (NC) SPECT, without the need for CT. <b>Methods:</b> SPECT myocardial perfusion imaging was performed using <sup>99m</sup>Tc-sestamibi or <sup>99m</sup>Tc-tetrofosmin on contemporary scanners with solid-state detectors. We developed a conditional generative adversarial neural network that applies a deep learning model (DeepAC) to generate simulated AC SPECT images. The model was trained with short-axis NC and AC images performed at 1 site (<i>n</i> = 4,886) and was tested on patients from 2 separate external sites (<i>n</i> = 604). We assessed the diagnostic accuracy of the stress total perfusion deficit (TPD) obtained from NC, AC, and DeepAC images for obstructive coronary artery disease (CAD) with area under the receiver-operating-characteristic curve. We also quantified the direct count change among AC, NC, and DeepAC images on a per-voxel basis. <b>Results:</b> DeepAC could be obtained in less than 1 s from NC images; area under the receiver-operating-characteristic curve for obstructive CAD was higher for DeepAC TPD (0.79; 95% CI, 0.72–0.85) than for NC TPD (0.70; 95% CI, 0.63–0.78; <i>P</i> < 0.001) and similar to AC TPD (0.81; 95% CI, 0.75–0.87; <i>P</i> = 0.196). The normalcy rate in the low-likelihood-of-coronary-disease population was higher for DeepAC TPD (70.4%) and AC TPD (75.0%) than for NC TPD (54.6%, <i>P</i> < 0.001 for both). The positive count change (increase in counts) was significantly higher for AC versus NC (median, 9.4; interquartile range, 6.0–14.2; <i>P</i> < 0.001) than for AC versus DeepAC (median, 2.4; interquartile range, 1.3–4.2). <b>Conclusion:</b> In an independent external dataset, DeepAC provided improved diagnostic accuracy for obstructive CAD, as compared with NC images, and this accuracy was similar to that of actual AC. DeepAC simplifies the task of artifact identification for physicians, avoids misregistration artifacts, and can be performed rapidly without the need for CT hardware and additional acquisitions.
18
Outcomes of Anatomical versus Functional Testing for Coronary Artery Disease
Pamela S. Douglas, Udo Hoffmann, Manesh R. Patel et al. · New England Journal of Medicine · 2015 · 1.5K citations · Full text
Daniel S. Berman, Rory Hachamovitch, Hosen Kiat et al. · Journal of the American College of Cardiology · 1995 · 590 citations