International Journal of Environmental Research and Public Health · 2022 · 13 citations · 16 references
ArchitectureArchitectural EngineeringBuilding ScienceBioclimatic DesignBuilding PhysicsThermal ComfortBuilding Cooling SystemsBuilding Thermal PerformanceIndoor Environmental ConditionsIndoor Thermal EnvironmentShading DesignThermal PerformanceCoolingHumidityIndoor Air TemperatureIndoor Humidity RegulationIndoor Thermal ComfortShadingShading Device PerformanceVertical Shading Devices
Previous studies have shown that vertical greening has a significant cooling and energy-saving effect, most of which are applied to opaque walls. However, windows are the critical factor contributing to the indoor thermal environment. This study developed a modular vertical greening shading device (MVGSD), and introduces its detailed structure: water supply mode, plant selection, and substrate preparation. To investigate the thermal performance of MVGSD, a structural model test was carried out. The results show that MVGSD has a noticeable effect on indoor temperature. Specifically, the greatest indoor temperature can be reduced by 4 °C and effectively low the concentration of CO2 (The CO2 absorption rate is 53.1%). In addition, the characteristics of the louver shading and MVGSD were compared, and it was found that the indoor temperature by using MVGSD is 2.6 °C lower than the louver. It is also worth mentioning that indoor humidity is improved by MVGSD, which has a beneficial effect on the thermal comfort of human beings.
16
Green vertical systems for buildings as passive systems for energy savings
Gabriel Pérez, Lídia Rincón, A. Vilà et al. · Applied Energy · 2011 · 420 citations · Full text
Engineering, Architectural Engineering, Building Science +16