Medical Physics · 2022 · 22 citations · 34 references
MedicineBioengineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyDiffusion ImagingImage QualityImage Quality AssessmentMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingApparent Diffusion Coefficient AnalysisContrast RatioDiagnostic Image Quality CriteriaDiffusion Magnetic Resonance ImagingImage Quality MetricsMedical Image Quality AssessmentSubjective Image Quality AssessmentT2-weighted Imaging
PURPOSE: The purpose of this study was to explore the feasibility of pancreatic imaging at 5 T and evaluate the practical improvement of T2-weighted MRI and diffusion-weighted imaging (DWI) at 5 T as compared with 3 T. METHODS: Eighteen healthy subjects were recruited for this pilot study. MRI examinations were performed using 3 and 5 T scanners. MRI sequences included T2-weighted fast spin-echo and DWI with reduced field-of-view. Subjective image analysis using a four-point Likert scale was performed by two experienced radiologists. The SNR, contrast ratio, and apparent diffusion coefficient (ADC) were measured in the pancreatic head, body, and tail. The coefficient of variation (CV) of the ADC was calculated. A series of paired Wilcoxon tests were used to compare the subjective image quality, mean ADC value, and CV of ADC between the 3 and 5 T measurements. p <0.05 was considered statistically significant. RESULTS: ), the image quality ratings were significantly higher at 5 T than at 3 T. The SNRs of both T2-weighted and DWI images were significantly higher at 5 T. There was no significant difference in the mean ADC values and CV of ADC between 3 and 5 T. CONCLUSION: This initial study proved that 5 T MRI can be used to acquire pancreatic images with higher SNR and sufficient image quality compared to 3 T MRI.
34
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Separation of diffusion and perfusion in intravoxel incoherent motion MR imaging.
Denis Le Bihan, D Lallemand, Michèle Aubin et al. · Radiology · 1988 · 3.2K citations
Gregory J. Metzger, Carl Snyder, Can Akgün et al. · Magnetic Resonance in Medicine · 2008 · 318 citations · Full text
Whole‐body imaging at 7T: Preliminary results
J. Thomas Vaughan, Carl Snyder, Lance DelaBarre et al. · Magnetic Resonance in Medicine · 2008 · 276 citations · Full text
DWI of the spinal cord with reduced FOV single‐shot EPI
Emine Ülkü Sarıtaş, Charles H. Cunningham, Jin Hyung Lee et al. · Magnetic Resonance in Medicine · 2008 · 267 citations
Medicine, Neuroscience, Radiology +14