Journal of Computer Assisted Tomography · 2022 · 13 citations · 18 references
Veterinary MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic ImagingCardiovascular ImagingChest RadiologyComputed TomographyImage Quality AssessmentPulmonary ImagingVascular ImagingComputed Tomography AngiographyComputed Tomography ReconstructionContrast EnhancementContrast-enhanced AngiographyCt Image ReconstructionPulmonary Artery AnatomyPulmonary Artery ImagingSubjective Image Quality Assessment
OBJECTIVE: This study aimed to evaluate chest computed tomography (CT) angiography image quality using the contrast enhancement (CE)-boost technique compared with conventional images. METHODS: Forty patients who underwent contrast-enhanced chest CT were included. Combined CT angiography images of the iodinated image obtained from the subtraction of nonenhanced CT images and CT angiography images were used to generate CE-boost images. Computed tomography attenuation, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) for the right and left pulmonary arteries as the central and subsegmental arteries as peripheral vessels were assessed. Subjective image quality was rated on a 5-point scale by 2 radiologists. Image quality was assessed using a paired t test. RESULTS: Computed tomography attenuation in the main pulmonary artery was significantly higher for the CE-boost images (311.05 ± 91.94) than for the conventional images (221.25 ± 61.21, P < 0.001). Similarly, the CE-boost images resulted in significantly higher CT attenuation in the subsegmental arteries (right, 305.34 ± 90.13; left, 313.05 ± 97.21) than in the conventional images (right, 218.45 ± 63.16; left, 223.89 ± 74.27). The CE-boost technique demonstrated marked improvement in the visualization of the peripheral pulmonary artery without the administration of a higher iodine delivery rate. The mean SNR and CNR were also significantly higher in the central and peripheral vessels in the CE-boost images than in the conventional images (P < 0.001). In the subjective analysis, the image contrast and vascular contrast edge were significantly higher for the CE-boost images than for conventional images (P < 0.001). CONCLUSIONS: The CE-boost technique increases not only the visualization of peripheral arteries by improving vascular attenuation but also the SNR and CNR.
18
Antithrombotic Therapy for VTE Disease
Clive Kearon, Elie A. Akl, Joseph Ornelas et al. · CHEST Journal · 2016 · 4.8K citations
Multidetector Computed Tomography for Acute Pulmonary Embolism
Paul D. Stein, Sarah Fowler, Lawrence R. Goodman et al. · New England Journal of Medicine · 2006 · 1.6K citations · Full text