BMC Medical Imaging · 2022 · 10 citations · 28 references
MedicineOncologyRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBreast Cancer ImagingBreast ImagingMedical Image AnalysisMedical ImagingSentinel Lymph Node BiopsySentinel Lymph Node ImagingApparent Diffusion Coefficient AnalysisAxillary Lymph Node EvaluationAxillary Lymph Node Involvement AssessmentAxillary Lymph Node MetastasisAxillary Sentinel Lymph Node BiopsyDiagnostic Performance MetricsDiffusion Coefficient EstimationMetastatic Lymph Node Burden
Abstract Background This study aims to estimate the amount of axillary lymph node (ALN) involvement in early-stage breast cancer utilizing a field of view (FOV) optimized and constrained undistorted single-shot (FOCUS) diffusion-weighted imaging (DWI) approach, as well as a whole-lesion histogram analysis. Methods This retrospective analysis involved 81 individuals with invasive breast cancer. The patients were divided into three groups: N 0 (negative ALN metastasis), N 1–2 (low metastatic burden with 1–2 ALNs), and N ≥3 (heavy metastatic burden with ≥ 3 ALNs) based on their sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND). Histogram parameters of apparent diffusion coefficient (ADC) depending basically on FOCUS DWI were performed using 3D-Slicer software for whole lesions. The typical histogram characteristics for N 0 , N 1–2 , and N ≥ 3 were compared to identify the significantly different parameters. To determine the diagnostic efficacy of significantly different factors, the area under their receiver operating characteristic (ROC) curves was examined. Results There were significant differences in the energy, maximum, 90 percentile, range, and lesion size among N 0 , N 1–2 , and N ≥ 3 groups ( P < 0.05). The energy differed significantly between N 0 and N 1–2 groups ( P < 0.05), and some certain ADC histogram parameters and lesion sizes differed significantly between N 0 and N ≥3 , or N 1–2 and N ≥3 groups. For ROC analysis, the energy yielded the best diagnostic performance in distinguishing N 0 and N 1–2 groups from N ≥3 group with an AUC value of0.853. All parameters revealed excellent inter-observer agreement with inter-reader consistencies data ranging from0.919 to 0.982. Conclusion By employing FOCUS DWI method, the analysis of whole-lesion ADC histogram quantitatively provides a non-invasive way to evaluate the degree of ALN metastatic spread in early-stage breast cancer.
28
João V. Horvat, Blanca Bernard‐Davila, Thomas H. Helbich et al. · Journal of Magnetic Resonance Imaging · 2019 · 104 citations · Full text
Jan J. Kootstra, Josette E. H. M. Hoekstra‐Weebers, Hans Rietman et al. · Annals of Surgical Oncology · 2008 · 84 citations · Full text