IEEE Transactions on Power Electronics · 2022 · 48 citations · 34 references
EngineeringElectrical EngineeringMechatronics EngineeringElectric MachinesMotor ControlPower ElectronicsDisturbance RejectionDrive SystemsElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsDrive System Stability AnalysisMotor Drive ControlPersistent ExcitationPosition EstimationReduced-order ControlRotor Position EstimationTorqueTorque Estimation
Harmonics and drifts are found in the position estimation errors of high-frequency signal injection (HFI) methods. To suppress the position estimation error, a hybrid active flux observer with disturbance rejection for both HFI method and model-based method is proposed. It fuses the position information from traditional HFI method and model-based method as the input of a disturbance observer, the estimated disturbance output can compensate measurement error for the two methods. Then a reduced-order natural speed observer is connected in a cascaded form to reject motor mechanical disturbance by estimating the load torque. Besides, a stator resistance identification algorithm is proposed, which is proved stable near zero frequency under persistent excitation condition. A tuning guideline for the whole algorithm is elaborated based on a rigorous stability analysis. Effective experiments and simulations verify the feasibility of the proposed scheme on a 0.75-kW interior permanent magnet synchronous motor drive platform.
34