Therapeutic Drug Monitoring · 2022 · 10 citations · 22 references
PharmacyPharmacokineticsPharmacologyChromatographic AnalysisClinical PharmacologyMass Spectrometric AnalysisBioanalytical Method ValidationCritical Care Therapeutic Drug MonitoringPharmacokinetics In Critical IllnessPharmacokinetics Of AntimicrobialsBeta-lactam Therapeutic Drug MonitoringHigh-performance Liquid Chromatography-mass SpectrometryLiquid Chromatography-mass SpectrometryLiquid Chromatography-mass Spectrometry AnalysisPharmacokinetics Of Antimicrobial AgentsQuantification Of AnalytesUltra-performance Liquid Chromatography-mass Spectrometryβ-Lactam Antibiotics
BACKGROUND: Optimization of antimicrobial therapy is a challenge in critically ill patients who develop extreme interindividual and intraindividual pharmacokinetic variability. Therapeutic drug monitoring is a valuable tool for maximizing the effect of a drug and minimizing its adverse and unwanted effects. The aim of the current work was to develop and validate an ultra-high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) method to determine multiple antibiotics in clinical plasma samples from critically ill patients; low sample volume and rapid processing of samples were considered the main criteria. METHODS: A separation method based on an online combination of UHPLC-MS/MS was developed for the simultaneous determination of 4 β-lactam antibiotics (cefepime, meropenem, cefotaxime, and piperacillin), tazobactam, and linezolid in human plasma samples. The volume of plasma sample used for analysis was 20 µL. The developed method was validated according to Food and Drug Administration guidelines. RESULTS: The chromatographic run time was 8 minutes. Calibration curves were linear for concentration ranges of 0.1-100 mcg/mL (r 2 > 0.99) for tazobactam, meropenem, cefotaxime, linezolid, and piperacillin and 1-100 mcg/mL (r 2 > 0.99) for cefepime. The intraday and interday accuracy of the method ranged from 92.4% to 110.7% and 93.6% to 113.3%, respectively. The intraday and interday precision values were ≤17.3% and ≤17.4%, respectively. No interfering and carryover analytes were observed. CONCLUSIONS: The developed UHPLC-MS/MS method is an appropriate and practical tool for therapeutic drug monitoring of the selected antibiotics. Owing to its rapidity, requirement of low sample volume, and high selectivity, sensitivity, and reliability, it can be effectively implemented in routine clinical laboratory tests for critically ill patients.
22
Marie‐Clémence Verdier, Olivier Tribut, Pierre Tattevin et al. · Antimicrobial Agents and Chemotherapy · 2011 · 151 citations · Full text
Raphaël Denooz, Corinne Charlier · Journal of Chromatography B · 2008 · 124 citations
Karin J. Vera-López, D. Faria Bertoluci, Karina Maria Vicente et al. · Journal of Chromatography B · 2007 · 111 citations