The Accuracy and Reliability of Visually Assessed Pharyngeal Opening Pressures During Drug‐Induced Sleep Endoscopy

Jason L. Yu, Eric Thuler, Everett G. Seay, Alan R. Schwartz, Raj C. Dedhia

Otolaryngology · 2022 · 14 citations · 22 references

DOIFull text

Open access

Abstract

DISE-PhOP, a measure of upper airway collapsibility, was equivalent between airflow-based and visual assessments with strong interrater reliability, supporting its adoption as a standardized objective parameter in clinical DISE.

References

22