European Radiology · 2022 · 24 citations · 18 references
MedicineBioengineeringRadiologyDiagnostic ImagingDiagnostic RadiologyNeuroradiologyBrain ImagingCerebrovascular ImagingComputed TomographyMedical ImagingNeurologic ImagingNeurovascular ImagingArtifact ReductionCt Image ReconstructionEnergy-integrating DetectorsImaging Artifact AssessmentMetal Artifact ReductionPhoton Counting DetectionPhoton-counting DetectorsReconstruction Of Metal Artifacts
OBJECTIVES: Photon-counting detector computed tomography (PCD-CT) is a promising new technique for CT imaging. The aim of the present study was the in vitro comparison of coil-related artifacts in PCD-CT and conventional energy-integrating detector CT (EID-CT) using a comparable standard brain imaging protocol before and after metal artifact reduction (MAR). METHODS: A nidus-shaped rubber latex, resembling an aneurysm of the cerebral arteries, was filled with neurovascular platinum coils and inserted into a brain imaging phantom. Image acquisition and reconstruction were repeatedly performed for PCD-CT and EID-CT (n = 10, respectively) using a standard brain imaging protocol. Moreover, linear interpolation MAR was performed for PCD-CT and EID-CT images. The degree of artifacts was analyzed quantitatively (standard deviation in a donut-shaped region of interest) and qualitatively (5-point scale analysis). RESULTS: Quantitative and qualitative analysis demonstrated a lower degree of metal artifacts in the EID-CT images compared to the total-energy PCD-CT images (e.g., 82.99 ± 7.89 Hounsfield units (HU) versus 90.35 ± 6.28 HU; p < 0.001) with no qualitative difference between the high-energy bin PCD-CT images and the EID-CT images (4.18 ± 0.37 and 3.70 ± 0.64; p = 0.575). After MAR, artifacts were more profoundly reduced in the PCD-CT images compared to the EID-CT images in both analyses (e.g., 2.35 ± 0.43 and 3.18 ± 0.34; p < 0.001). CONCLUSION: PCD-CT in combination with MAR have the potential to provide an improved option for reduction of coil-related artifacts in cerebral imaging in this in vitro study. KEY POINTS: • Photon-counting detector CT produces more artifacts compared to energy-integrating detector CT without metal artifact reduction in cerebral in vitro imaging after neurovascular coil-embolization. • Spectral information of PCD-CT provides the potential for new post-processing techniques, since the coil-related artifacts were lower in PCD-CT images compared to EID-CT images after linear interpolation metal artifact reduction in this in vitro study.
18
Interrater reliability: the kappa statistic
Marry L. McHugh · Biochemia Medica · 2012 · 18.6K citations · Full text
Guidelines for the Management of Aneurysmal Subarachnoid Hemorrhage
E. Sander Connolly, Alejandro A. Rabinstein, J. Ricardo Carhuapoma et al. · Stroke · 2012 · 3.5K citations · Full text
Reduction of CT artifacts caused by metallic implants.
Willi A. Kalender, R. Hebel, J. C. W. Ebersberger · Radiology · 1987 · 743 citations