EJNMMI Radiopharmacy and Chemistry · 2022 · 25 citations · 15 references
MedicineNuclear MedicinePharmacologyMolecular ImagingSynthetic Medicinal ChemistryTheranosticsPositron Emission TomographyRadiopharmaceuticalsAutomated Synthesis ModulesCation ExchangeFibroblast ActivationFibroblast Activation Protein ImagingFluorine-18 Fluorodeoxyglucose Positron Emission TomographyPositron Emission Tomography DetectionRadiotracer AnalysisRadiotracer Synthesis
Abstract Background The recent development of quinoline-based radiotracers, which act as fibroblast activation protein inhibitors (FAPIs), has shown promising preclinical and clinical advantages. [ 68 Ga]Ga-FAPI-46 is a new radiotracer for in vivo detection of the fibroblast activation protein by positron emission tomography (PET). Recently, the automated synthesis of [ 68 Ga]Ga-FAPI-46 was reported based on pre-concentration and purification of the generator eluate by using a cation exchange-cartridge. Our aim was to simplify the synthesis and shorten the automated synthesis of [ 68 Ga]Ga-FAPI-46 to make it accessible and thus even more attractive to a broader clinical and scientific community. Results We developed and evaluated the GMP compliant automatic synthesis of [ 68 Ga]Ga-FAPI-46 using two different 68 Ge/ 68 Ga generators (an Eckert & Ziegler, GalliaPharm generator, 1.85 GBq/50 mCi and an iThemba generator, 1.85 GBq/50 mCi) Somerset West, South Africa) and three different commercial and customized systems: the EasyOne module from Trasis; the GaSy module from Synthra with a customized synthesis template and a customized single use cassette. Additionally, the automatic synthesis of [ 68 Ga]Ga-FAPI-46 was established on a GallElut synthesis module from Scintomics with fixed tubing. Conclusions Independent of the synthesis modules or the generators employed we were able to complete the synthesis of [ 68 Ga]Ga-FAPI-46 in 12 min including the process of purification and formulation. In all cases, the final products showed more than 99.5% chemical purity and the radiochemical yield reached around 92.5% (decay corrected). All quality control parameters (e.g. sterility, stability and radiochemical purity) were conform to the European Pharmacopoeia.
15
<sup>68</sup>Ga-FAPI PET/CT: Tracer Uptake in 28 Different Kinds of Cancer
Clemens Kratochwil, Paul Flechsig, Thomas Lindner et al. · Journal of Nuclear Medicine · 2019 · 1.4K citations · Full text
Medicine, Nuclear Medicine, Oncology +17
Zohreh Varasteh, Sarajo K. Mohanta, Stephanie Robu et al. · Journal of Nuclear Medicine · 2019 · 246 citations · Full text