NMR in Biomedicine · 2022 · 11 citations · 42 references
MedicineBioengineeringRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyBrain ImagingDiffusion ImagingMagnetic Resonance Image ReconstructionMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsMedical ImagingDenoisingImage DenoisingMagnetic Resonance PhysicsSignal DenoisingSpin Echo ImagingT2 RelaxationTransverse RelaxationTransverse Relaxation Time
High‐resolution mapping of magnetic resonance imaging (MRI)’s transverse relaxation time (T 2 ) can benefit many clinical applications by offering improved anatomic details, enhancing the ability to probe tissues’ microarchitecture, and facilitating the identification of early pathology. Increasing spatial resolutions, however, decreases data's signal‐to‐noise ratio (SNR), particularly at clinical scan times. This impairs imaging quality, and the accuracy of subsequent radiological interpretation. Recently, principal component analysis (PCA) was employed for denoising diffusion‐weighted MR images and was shown to be effective for improving parameter estimation in multiexponential relaxometry. This study combines the Marchenko–Pastur PCA (MP‐PCA) signal model with the echo modulation curve (EMC) algorithm for denoising multiecho spin‐echo (MESE) MRI data and improving the precision of EMC‐generated single T 2 relaxation maps. The denoising technique was validated on simulations, phantom scans, and in vivo brain and knee data. MESE scans were performed on a 3‐T Siemens scanner. The acquired images were denoised using the MP‐PCA algorithm and were then provided as input for the EMC T 2 ‐fitting algorithm. Quantitative analysis of the denoising quality included comparing the standard deviation and coefficient of variation of T 2 values, along with gold standard SNR estimation of the phantom scans. The presented denoising technique shows an increase in T 2 maps' precision and SNR, while successfully preserving the morphological features of the tissue. Employing MP‐PCA denoising as a preprocessing step decreases the noise‐related variability of T 2 maps produced by the EMC algorithm and thus increases their precision. The proposed method can be useful for a wide range of clinical applications by facilitating earlier detection of pathologies and improving the accuracy of patients' follow‐up.
42
Bilateral filtering for gray and color images
Carlo Tomasi, Roberto Manduchi · 2002 · 8.1K citations
Arts, Vision Science, Color Vision +16
The rician distribution of noisy mri data
Hákon Guðbjartsson, Samuel Patz · Magnetic Resonance in Medicine · 1995 · 2.5K citations
Denoising of diffusion MRI using random matrix theory
Jelle Veraart, Dmitry S. Novikov, Daan Christiaens et al. · NeuroImage · 2016 · 2K citations · Full text