Fracture Resistance of Three-unit Fixed Dental Prostheses Fabricated with Milled and 3D Printed Composite-based Materials.

Karim Corbani, Louis Hardan, Rita Eid, Hasan Skienhe, Nawal Alharbi, Mutlu Özcan, Ziad Salameh

PubMed · 2021 · 12 citations · 0 references

Concepts

Abstract

AIM: To evaluate the fracture resistance of three-unit fixed dental prosthesis (FDP) made of composite, high-density polymers (HDP), fiber-reinforced composite (FRC), and metal-ceramic (MC) using different fabrication methods. MATERIALS AND METHODS: test (α = 0.05). RESULTS: The MC group reported the highest fracture resistance with a statistically significant difference (2390.87 ± 166.28 N) compared to other groups. No significance was noted between 3DP and HDP groups (1360.20 ± 148.15 N and 1312.27 ± 64.40 N, respectively), while the FRC group displayed the lowest value (839.07 ± 54.30 N). The higher frequency of nonrepairable failures was observed in the MC and FRC groups, while HDP and 3DP groups reported a high frequency of repairable failures. CONCLUSION: Significant differences were found in fracture resistance between the tested groups. The load-bearing capacity of the composite-based FPDs exceeded the range of maximum chewing forces. CLINICAL SIGNIFICANCE: 3D printed and milled composite-based materials might offer a suitable solution for the fabrication of FPDs.