Frontiers in Neuroscience · 2022 · 21 citations · 45 references
Health ProfessionsAudiologyOtolaryngologyElectrophysiologyHearing AssessmentHearing ScienceCochlear FunctionCochlear ImplantationCochlear NeuroscienceResidual Hearing PreservationSurgical ImplantationCochlear ElectrodesCochlear Hearing Loss AssessmentCochlear PathophysiologyResidual Low-frequency Hearing
Objectives Electrocochleography (ECochG) recordings during cochlear implantation have shown promise in estimating the impact on residual hearing. The purpose of the study was (1) to determine whether a 250-Hz stimulus is superior to 500-Hz in detecting residual hearing decrement and if so; (2) to evaluate whether crossing the 500-Hz tonotopic, characteristic frequency (CF) place partly explains the problems experienced using 500-Hz. Design Multifrequency ECochG comprising an alternating, interleaved acoustic complex of 250- and 500-Hz stimuli was used to elicit cochlear microphonics (CMs) during insertion. The largest ECochG drops (≥30% reduction in CM) were identified. After insertion, ECochG responses were measured using the individual electrodes along the array for both 250- and 500-Hz stimuli. Univariate regression was used to predict whether 250- or 500-Hz CM drops explained low-frequency pure tone average (LFPTA; 125-, 250-, and 500-Hz) shift at 1-month post-activation. Postoperative CT scans were performed to evaluate cochlear size and angular insertion depth. Results For perimodiolar insertions ( N = 34), there was a stronger linear correlation between the largest ECochG drop using 250-Hz stimulus and LFPTA shift ( r = 0.58), compared to 500-Hz ( r = 0.31). The 250- and 500-Hz CM insertion tracings showed an amplitude peak at two different locations, with the 500-Hz peak occurring earlier in most cases than the 250-Hz peak, consistent with tonotopicity. When using the entire array for recordings after insertion, a maximum 500-Hz response was observed 2–6 electrodes basal to the most-apical electrode in 20 cases (58.9%). For insertions where the apical insertion angle is >350 degrees and the cochlear diameter is <9.5 mm, the maximum 500-Hz ECochG response may occur at the non-apical most electrode. For lateral wall insertions ( N = 14), the maximum 250- and 500-Hz CM response occurred at the most-apical electrode in all but one case. Conclusion Using 250-Hz stimulus for ECochG feedback during implantation is more predictive of hearing preservation than 500-Hz. This is due to the electrode passing the 500-Hz CF during insertion which may be misidentified as intracochlear trauma; this is particularly important in subjects with smaller cochlear diameters and deeper insertions. Multifrequency ECochG can be used to differentiate between trauma and advancement of the apical electrode beyond the CF.
45
Factors Affecting Open-Set Word Recognition in Adults With Cochlear Implants
Laura K. Holden, Charles C. Finley, Jill B. Firszt et al. · Ear and Hearing · 2013 · 964 citations
Music Perception with Cochlear Implants and Residual Hearing
Kate Gfeller, Carol Olszewski, Christopher W. Turner et al. · Audiology and Neurotology · 2006 · 250 citations
Variations in microanatomy of the human cochlea
Ersin Avci, Tim Nauwelaers, Thomas Lenarz et al. · The Journal of Comparative Neurology · 2014 · 220 citations · Full text