Frontiers in Cardiovascular Medicine · 2022 · 10 citations · 31 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyElectrophysiologyCardiac ArrhythmiasCardiac Risk AssessmentElectrocardiogram AnalysisElectrocardiographyArrhythmic Risk AssessmentElectrocardiographic PatternsElectrocardiographic Risk AssessmentImplantable Cardioverter DefibrillatorsLife-threatening Arrhythmias
Introduction Predictors of late life-threatening arrhythmic events in Brugada syndrome (BrS) patients who received a prophylactic ICD implantation remain to be evaluated. The aim of the present long-term multicenter study was to assess the incidence and clinical-electrocardiographic predictors of late life-threatening arrhythmic events in BrS patients with a prophylactic implantable cardioverter defibrillator (ICD) and undergoing generator replacement (GR). Methods The study population included 105 patients (75% males; mean age 45 ± 14years) who received a prophylactic ICD and had no arrhythmic event up to first GR. Results The median period from first ICD implantation to last follow-up was 155 (128–181) months and from first ICD Implantation to the GR was 84 (61–102) months. During a median follow-up of 57 (38–102) months after GR, 10 patients (9%) received successful appropriate ICD intervention (1.6%/year). ICD interventions included shock on ventricular fibrillation ( n = 8 patients), shock on ventricular tachycardia ( n = 1 patient), and antitachycardia pacing on ventricular tachycardia ( n = 1 patient). At survival analysis, history of atrial fibrillation (log-rank test; P = 0.02), conduction disturbances (log-rank test; P < 0.01), S wave in lead I (log-rank test; P = 0.01) and first-degree atrioventricular block (log-rank test; P = 0.04) were significantly associated with the occurrence of late appropriate ICD intervention. At Cox-regression multivariate analysis, S-wave in lead I was the only independent predictor of late appropriate ICD intervention (HR: 9.17; 95%CI: 1.15–73.07; P = 0.03). Conclusions The present study indicates that BrS patient receiving a prophylactic ICD may experience late appropriate intervention after GR in a clinically relevant proportion of cases. S-wave in lead I at the time of first clinical evaluation was the only independent predictor of persistent risk of life-threatening arrhythmic events. These findings support the need for GR at the end of service regardless of previous appropriate intervention, mostly in BrS patients with conduction abnormalities.
31
2018 ESC Guidelines for the diagnosis and management of syncope
Michele Brignole, Frederik J. de Lange, Jean‐Claude Deharo et al. · European Heart Journal · 2018 · 1.9K citations · Full text
Long-Term Prognosis of Patients Diagnosed With Brugada Syndrome
Vincent Probst, Christian Veltmann, Lars Eckardt et al. · Circulation · 2010 · 846 citations · Full text
Risk Stratification in Brugada Syndrome
Silvia G. Priori, Maurizio Gasparini, Carlo Napolitano et al. · Journal of the American College of Cardiology · 2011 · 579 citations
Hiroshi Morita, Kengo Kusano, Daiji Miura et al. · Circulation · 2008 · 477 citations
Medicine, Cardiology, Neurology +13
Subcutaneous or Transvenous Defibrillator Therapy
Reinoud E. Knops, Louise R.A. Olde Nordkamp, Peter-Paul Delnoy et al. · New England Journal of Medicine · 2020 · 470 citations · Full text
Medicine, Cardiology, Surgery +14