Physiological Measurement · 2022 · 83 citations · 32 references
MedicineCardiologyBioinstrumentationBiomedical Signal ProcessingElectrophysiologyCardiac Signal ProcessingCardiovascular MonitoringElectrocardiographySignal EvaluationVital SignsWearable Health TechnologiesCardiac Monitoring SystemsPhotoplethysmogram Signal ProcessingPositive Predictive ValuePositive Predictive Value AnalysisPulse OximetersWearable Vital Signs Sensors
Abstract The photoplethysmogram (PPG) signal is widely used in pulse oximeters and smartwatches. A fundamental step in analysing the PPG is the detection of heartbeats. Several PPG beat detection algorithms have been proposed, although it is not clear which performs best. Objective: This study aimed to: (i) develop a framework with which to design and test PPG beat detectors; (ii) assess the performance of PPG beat detectors in different use cases; and (iii) investigate how their performance is affected by patient demographics and physiology. Approach: Fifteen beat detectors were assessed against electrocardiogram-derived heartbeats using data from eight datasets. Performance was assessed using the F 1 score, which combines sensitivity and positive predictive value. Main results: Eight beat detectors performed well in the absence of movement with F 1 scores of ≥90% on hospital data and wearable data collected at rest. Their performance was poorer during exercise with F 1 scores of 55%–91%; poorer in neonates than adults with F 1 scores of 84%–96% in neonates compared to 98%–99% in adults; and poorer in atrial fibrillation (AF) with F 1 scores of 92%–97% in AF compared to 99%–100% in normal sinus rhythm. Significance: Two PPG beat detectors denoted ‘MSPTD’ and ‘qppg’ performed best, with complementary performance characteristics. This evidence can be used to inform the choice of PPG beat detector algorithm. The algorithms, datasets, and assessment framework are freely available.
32
PhysioBank, PhysioToolkit, and PhysioNet
Ary L. Goldberger, Luı́s A. Nunes Amaral, Leon Glass et al. · Circulation · 2000 · 14.5K citations · Full text
MIMIC-III, a freely accessible critical care database
Alistair E. W. Johnson, Tom Pollard, Lu Shen et al. · Scientific Data · 2016 · 8.1K citations · Full text
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Marco Pérez, Kenneth W. Mahaffey, Haley Hedlin et al. · New England Journal of Medicine · 2019 · 1.9K citations · Full text
Introducing WESAD, a Multimodal Dataset for Wearable Stress and Affect Detection
Philip Schmidt, Attila Reiss, Robert Duerichen et al. · 2018 · 1.2K citations