European Journal of Nuclear Medicine and Molecular Imaging · 2022 · 31 citations · 46 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyAttenuation CorrectionComputed TomographyMedical ImagingPositron Emission TomographyPositron Emission Tomography PhysicsAttenuation Map GenerationBackground Radiation CorrectionBackground Radiation MappingConvolutional Neural NetworksHounsfield UnitsPet Attenuation CorrectionPet Image ReconstructionPositron Emission Tomography Attenuation Correction
Abstract Purpose Attenuation correction is a critically important step in data correction in positron emission tomography (PET) image formation. The current standard method involves conversion of Hounsfield units from a computed tomography (CT) image to construct attenuation maps (µ-maps) at 511 keV. In this work, the increased sensitivity of long axial field-of-view (LAFOV) PET scanners was exploited to develop and evaluate a deep learning (DL) and joint reconstruction-based method to generate µ-maps utilizing background radiation from lutetium-based (LSO) scintillators. Methods Data from 18 subjects were used to train convolutional neural networks to enhance initial µ-maps generated using joint activity and attenuation reconstruction algorithm (MLACF) with transmission data from LSO background radiation acquired before and after the administration of 18 F-fluorodeoxyglucose ( 18 F-FDG) (µ-map MLACF-PRE and µ-map MLACF-POST respectively). The deep learning-enhanced µ-maps (µ-map DL-MLACF-PRE and µ-map DL-MLACF-POST ) were compared against MLACF-derived and CT-based maps (µ-map CT ). The performance of the method was also evaluated by assessing PET images reconstructed using each µ-map and computing volume-of-interest based standard uptake value measurements and percentage relative mean error (rME) and relative mean absolute error (rMAE) relative to CT-based method. Results No statistically significant difference was observed in rME values for µ-map DL-MLACF-PRE and µ-map DL-MLACF-POST both in fat-based and water-based soft tissue as well as bones, suggesting that presence of the radiopharmaceutical activity in the body had negligible effects on the resulting µ-maps. The rMAE values µ-map DL-MLACF-POST were reduced by a factor of 3.3 in average compared to the rMAE of µ-map MLACF-POST . Similarly, the average rMAE values of PET images reconstructed using µ-map DL-MLACF-POST (PET DL-MLACF-POST ) were 2.6 times smaller than the average rMAE values of PET images reconstructed using µ-map MLACF-POST . The mean absolute errors in SUV values of PET DL-MLACF-POST compared to PET CT were less than 5% in healthy organs, less than 7% in brain grey matter and 4.3% for all tumours combined. Conclusion We describe a deep learning-based method to accurately generate µ-maps from PET emission data and LSO background radiation, enabling CT-free attenuation and scatter correction in LAFOV PET scanners.
46
U-Net: deep learning for cell counting, detection, and morphometry
Thorsten Falk, Dominic Mai, Robert Bensch et al. · Nature Methods · 2018 · 2K citations
Life Sciences, Biology, Cell Biology +14
A combined PET/CT scanner for clinical oncology.
Thomas Beyer, D.W. Townsend, T. Brun et al. · PubMed · 2000 · 1.6K citations
Attenuation correction for a combined 3D PET/CT scanner
Paul E. Kinahan, D.W. Townsend, Thomas Beyer et al. · Medical Physics · 1998 · 933 citations
Performance Characteristics of the Digital Biograph Vision PET/CT System
Joyce van Sluis, Johan de Jong, Jenny Schaar et al. · Journal of Nuclear Medicine · 2019 · 485 citations · Full text