BMC Pulmonary Medicine · 2022 · 10 citations · 19 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyPulmonologyBiopsy TechniquesChest RadiologyComputed TomographyImage-guided BiopsyPulmonary ImagingPulmonary PathologyDiagnostic Accuracy StudiesGround-glass Opacity AssessmentGround-glass Opacity PatternsGuided Core Needle BiopsyImage-guided Pulmonary DiagnosisLogistic RegressionOpacity
BACKGROUND: The diagnostic accuracy of computed tomography (CT)-guided percutaneous core needle biopsy (CNB) for small (≤ 20 mm) ground-glass opacity (GGO) lesions has not been reported in detail. OBJECTIVES: To evaluate factors that affect the diagnostic accuracy of CT-guided percutaneous CNB for small (≤ 20 mm) GGO pulmonary lesions. METHODS: From January 2014 to February 2018, 156 patients with a small (≤ 20 mm) GGO pulmonary lesion who underwent CT-guided CNB were enrolled in this study. Factors affecting diagnostic accuracy were evaluated by analyzing patient and lesion characteristics and technical factors. Significant factors were identified by multivariate logistic regression. RESULTS: The diagnostic accuracy of CT-guided percutaneous CNB was 90.4% for small (≤ 20 mm) GGO pulmonary lesions. The diagnostic accuracy was higher for larger lesions (72.5% for lesions ≤ 10 mm, 96.6% for lesions between 11 and 20 mm [P < 0.001]). The diagnostic accuracy of CT-guided percutaneous CNB was 74.5% for lesions with > 90% GGO components and 97.2% for lesions with 50-90% GGO components (P < 0.001). In multivariate analysis, the significant factors influencing diagnostic accuracy were lesion size (P = 0.022; odds ratio [OR] for a lesion between 11 and 20 mm in size was approximately 5 times higher than that for a lesion ≤ 10 mm; 95% confidence interval [CI], 1.3 to 18.5), and GGO component (P = 0.015; OR for a lesion with 50-90% GGO components was approximately 6 times higher than that for a lesion with > 90% GGO components; 95% CI: 1.4 to 25.7). CONCLUSIONS: Lesion size and GGO component are factors affecting diagnostic accuracy. The diagnostic accuracy was higher for larger lesions and lesions with 50-90% GGO components.
19
Persistent Pulmonary Nodular Ground-Glass Opacity at Thin-Section CT: Histopathologic Comparisons
Young Mog Shim, Kyung Soo Lee, Joungho Han et al. · Radiology · 2007 · 379 citations
Persistent Pure Ground-Glass Opacity Lung Nodules ≥ 10 mm in Diameter at CT Scan
Hyun-ju Lim, Soomin Ahn, Kyung Soo Lee et al. · CHEST Journal · 2013 · 256 citations
CT-guided percutaneous core needle biopsy for small (≤20 mm) pulmonary lesions
Y. Li, Yuchen Du, Hanfeng Yang et al. · Clinical Radiology · 2012 · 137 citations