IEEE Transactions on Biomedical Engineering · 2022 · 28 citations · 29 references
ComputingData ScienceHealth InformaticsMachine LearningSleep MedicineTime Series AnalysisDeep LearningSleep AssessmentSleep PhysiologySleep Signal AnalysisTime Series ClassificationWearable Health TechnologiesDeep Learning For Sleep AnalysisFeature Extraction From Sleep SignalsMultivariate Time Series ClassificationSleep Signal ClassificationSleep Stage ClassificationSleep StagesSleep-wake State MonitoringValidation Studies
Wrist-worn consumer sleep technologies (CST) that contain accelerometers (ACC) and photoplethysmography (PPG) are increasingly common and hold great potential to function as out-of-clinic (OOC) sleep monitoring systems. However, very few validation studies exist because raw data from CSTs are rarely made accessible for external use. We present a deep neural network (DNN) with a strong temporal core, inspired by U-Net, that can process multivariate time series inputs with different dimensionality to predict sleep stages (wake, light-, deep-, and REM sleep) using ACC and PPG signals from nocturnal recordings. The DNN was trained and tested on 3 internal datasets, comprising raw data both from clinical and wrist-worn devices from 301 recordings (PSG-PPG: 266, Wrist-worn PPG: 35). External validation was performed on a hold-out test dataset containing 35 recordings comprising only raw data from a wrist-worn CST. An accuracy = 0.71 ± 0.09, 0.76 ± 0.07, 0.73 ± 0.06, and κ = 0.58 ± 0.13, 0.64 ± 0.09, 0.59 ± 0.09 was achieved on the internal test sets. Our experiments show that spectral preprocessing yields superior performance when compared to surrogate-, feature-, raw data-based preparation. Combining both modalities produce the overall best performance, although PPG proved to be the most impactful and was the only modality capable of detecting REM sleep well. Including ACC improved model precision to wake and sleep metric estimation. Increasing input segment size improved performance consistently; the best performance was achieved using 1024 epochs (∼8.5 hrs.). An accuracy = 0.69 ± 0.13 and κ = 0.58 ± 0.18 was achieved on the hold-out test dataset, proving the generalizability and robustness of our approach to raw data collected with a wrist-worn CST.
29
Gaussian Error Linear Units (GELUs)
Dan Hendrycks, Kevin Gimpel · arXiv (Cornell University) · 2016 · 3.2K citations · Full text
Class-Balanced Loss Based on Effective Number of Samples
Yin Cui, Menglin Jia, Tsung-Yi Lin et al. · 2019 · 2.6K citations
Automatic Sleep/Wake Identification From Wrist Activity
Roger J. Cole, Daniel F. Kripke, William Gruen et al. · SLEEP · 1992 · 1.9K citations · Full text
National Sleep Foundation's sleep quality recommendations: first report
Maurice M. Ohayon, Emerson M. Wickwire, Max Hirshkowitz et al. · Sleep Health · 2016 · 1.3K citations · Full text
André Henriksen, Martin Haugen Mikalsen, Ashenafi Zebene Woldaregay et al. · Journal of Medical Internet Research · 2018 · 554 citations · Full text
Education, Health Informatics, Consumer Health Informatics +16