IEEE Transactions on Biomedical Engineering · 2022 · 16 citations · 34 references
EngineeringBioengineeringNeuroscienceBiomedical Signal ProcessingNeural EngineeringNeurophysiologyBiopotential MeasurementIntracranial PressureIntracranial Pressure MonitoringElectromechanical ModelingIntracranial Pressure DynamicsIntracranial Pressure Monitoring DevicesInvasive Brain MonitoringNoninvasive DiagnosticsNoninvasive Intracranial Pressure EstimationNoninvasive Intracranial Pressure MonitoringTissue Dielectric Constant Measurement
<italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Objective:</i> The clinical management of several neurological disorders benefits from the assessment of intracranial pressure and craniospinal compliance. However, the associated procedures are invasive in nature. Here, we aimed to assess whether naturally occurring periodic changes in the dielectric properties of the head could serve as the basis for deriving surrogates of craniospinal compliance noninvasively. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Methods:</i> We designed a device and electrodes for noninvasive measurement of periodic changes of the dielectric properties of the human head. We characterized the properties of the device-electrode-head system by measurements on healthy volunteers, by computational modeling, and by electromechanical modeling. We then performed hyperventilation testing to assess whether the measured signal is of intracranial origin. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Results:</i> Signals obtained with the device on volunteers showed characteristic cardiac and respiratory modulations. Signal oscillations can be attributed primarily to changes in resistive properties of the head during cardiac and respiratory cycles. Reduction of end-tidal CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> , through hyperventilation, resulted in a decrease in the signal amplitude associated with cardiovascular action. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Conclusion:</i> Given the higher CO <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">2</sub> reactivity of intracranial vessels compared to extracranial ones, the results of hyperventilation testing suggest that the acquired signal is, in part, of intracranial origin. <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">Significance:</i> If confirmed in larger cohorts, our observations suggest that noninvasive capacitive acquisition of changes in the dielectric properties of the head could be used to derive surrogates of craniospinal compliance.
34
Guidelines for the Management of Severe Traumatic Brain Injury, Fourth Edition
Nancy Carney, Annette M Totten, Cindy O’Reilly et al. · Neurosurgery · 2016 · 4.3K citations
CSF pressure assessed by lumbar puncture agrees with intracranial pressure
Niklas Lenfeldt, Lars‐Owe Koskinen, A. Tommy Bergenheim et al. · Neurology · 2007 · 169 citations
Medicine, Neuroscience, Neurosurgery +16