Clinical Implant Dentistry and Related Research · 2022 · 11 citations · 46 references
DentistryImplant DentistryMaxillofacial SurgeryDentoalveolar SurgeryImplant ProsthodonticsImplant SurgeryOcclusal Scheme For Implant ProsthesesPeri-implant Bone Level AssessmentPeri-implant Tissue HealthBar Attachment SystemsDental ImplantsHader Bar SystemsMandibular Implant-supported OverdenturesMandibular Posterior Implant SitesPeri-implant Tissue AssessmentPosterior Segment ImplantsSurgical Implants
INTRODUCTION: This study aimed to evaluate peri-implant tissue health and patient satisfaction of vertical and inclined posterior implants for mandibular bar overdentures. MATERIALS AND METHODS: Thirty edentulous participants received four implants in the interforaminal area of the mandible. The patients were randomly assigned into two equal groups; (1) vertical group (control): all implants were inserted vertically parallel to each other. Inclined group (study): the anterior implants were placed vertically, and the posterior implants were tilted 30° distally. Hader bar attachment with two 7 mm-distal cantilevers (vertical group) and without cantilevers (inclined group) was used to connect the implants to mandibular overdentures. Peri-implant tissue health (Plaque [PL] and gingival [GI] indices, pocket depth [PD], and crestal bone loss [CBL]) were evaluated after denture insertion (T0), 6 (T6), and 12 (T12) months after insertion. Patient satisfaction was evaluated using a visual analog scale after 12 months. RESULTS: At T12, the vertical group showed significantly higher PL, PD, and CBL than the inclined group for anterior (p < 0.037) and posterior (p < 0.017) implants. The vertical group showed significantly higher GI than the inclined group for anterior implants (p = 0.003), and the inclined group showed significantly higher GI than the vertical group for posterior implants (p = 0.016). The inclined group showed significantly higher scores for general satisfaction (p = 0.049), prosthesis as a part of you (p = 0.013), appearance (p < 0.001), stability (p = 0.002), ease of cleaning (p < 0.001), and comfort (p = 0.001) than the vertical group. CONCLUSION: Inclined posterior implants used to support mandibular bar overdentures are recommended than vertical implants, as it was associated with improved patient satisfaction and peri-implant tissue health.
46
Paulo Maló, Bo Rangert, Miguel de Araújo Nobre · Clinical Implant Dentistry and Related Research · 2003 · 763 citations
Tilting of posterior mandibular and maxillary implants for improved prosthesis support.
Leonard Krekmanov, M. Kahn, Bo Rangert et al. · PubMed · 2000 · 445 citations
Manal Awad, James P. Lund, Eric M. Đufresne et al. · Journal of Prosthetic Dentistry · 2003 · 267 citations