ASAIO Journal · 2022 · 13 citations · 21 references
MedicineChild HealthPediatricsPulmonologyVentilationVentilator ManagementAcute Respiratory FailureExtracorporeal Life SupportExtracorporeal Membrane OxygenationMechanical VentilationPositive End-expiratory PressureVentilatory SupportFractional Inspired OxygenLung-protective Ventilation In ChildrenPediatric Acute Respiratory FailurePediatric Extracorporeal Life SupportPediatric Extracorporeal Membrane OxygenationRespiratory Failure SupportRespiratory Gas ExchangeVentilator Support Decisions
Extracorporeal life support (ECLS) is a treatment for acute respiratory failure that can provide extracorporeal gas exchange, allowing lung rest. However, while most patients remain mechanically ventilated during ECLS, there is a paucity of evidence to guide the choice of ventilator settings. We studied the associations between ventilator settings 24 hours after ECLS initiation and mortality in pediatric patients using a retrospective analysis of data from the Extracorporeal Life Support Organization Registry. 3497 patients, 29 days to 18 years of age, treated with ECLS for respiratory failure between 2015 and 2021, were included for analysis. 93.3% of patients on ECLS were ventilated with conventional mechanical ventilation. Common settings included positive end-expiratory pressure (PEEP) of 10 cm H 2 O (45.7%), delta pressure (ΔP) of 10 cm H 2 O (28.3%), rate of 10-14 breaths per minute (55.9%), and fraction of inspired oxygen (FiO 2 ) of 0.31-0.4 (30.3%). In a multivariate model, PEEP >10 cm H 2 O ( versus PEEP < 8 cm H 2 O, odds ratio [OR]: 1.53, 95% CI: 1.20-1.96) and FiO 2 ≥0.45 ( versus FiO 2 < 0.4; 0.45 ≤ FiO 2 < 0.6, OR: 1.31, 95% CI: 1.03-1.67 and FiO 2 ≥ 0.6, OR: 2.30; 95% CI: 1.81-2.93) were associated with higher odds of mortality. In a secondary analysis of survivors, PEEP 8-10 cm H 2 O was associated with shorter ECLS run times ( versus PEEP < 8 cm H 2 O, coefficient: -1.64, 95% CI: -3.17 to -0.11), as was ΔP >16 cm H 2 O ( versus ΔP < 10 cm H 2 O, coefficient: -2.72, 95% CI: -4.30 to -1.15). Our results identified several categories of ventilator settings as associated with mortality or ECLS run-time. Further studies are necessary to understand whether these results represent a causal relationship.
21
Giles J. Peek, Miranda Mugford, Ravindranath Tiruvoipati et al. · The Lancet · 2009 · 3.4K citations
Medicine, Respiratory Therapy, Cost-effectiveness Analysis +11
Chris Feudtner, James A. Feinstein, Wenjun Zhong et al. · BMC Pediatrics · 2014 · 1.7K citations · Full text
Health Professions, Pediatrics, Clinical Classification Systems +16
Pediatric Acute Respiratory Distress Syndrome
Pediatric Critical Care Medicine · 2015 · 851 citations · Full text
Medicine, Child Health, Pediatrics +17