Neurogastroenterology & Motility · 2022 · 54 citations · 15 references
MedicineClinical SciencesHealth InformaticsBioinstrumentationBiomedical ImagingGastroenterologyArtifact RecognitionArtifact RejectionDiagnostic Test EvaluationGastrointestinal AssessmentMedical InstrumentationPoint-of-care DiagnosticsArtifact DetectionArtifact Detection AlgorithmsArtifact MappingAutomated Artifact RejectionElectrogastrographyInter-rater AgreementInter-rater ReliabilityInter-rater Reliability Assessment
BACKGROUND: Body surface gastric mapping (BSGM) is a new clinical tool for gastric motility diagnostics, providing high-resolution data on gastric myoelectrical activity. Artifact contamination was a key challenge to reliable test interpretation in traditional electrogastrography. This study aimed to introduce and validate an automated artifact detection and rejection system for clinical BSGM applications. METHODS: Ten patients with chronic gastric symptoms generated a variety of artifacts according to a standardized protocol (176 recordings) using a commercial BSGM system (Alimetry, New Zealand). An automated artifact detection and rejection algorithm was developed, and its performance was compared with a reference standard comprising consensus labeling by 3 analysis experts, followed by comparison with 6 clinicians (3 untrained and 3 trained in artifact detection). Inter-rater reliability was calculated using Fleiss' kappa. KEY RESULTS: Inter-rater reliability was 0.84 (95% CI:0.77-0.90) among experts, 0.76 (95% CI:0.68-0.83) among untrained clinicians, and 0.71 (95% CI:0.62-0.79) among trained clinicians. The sensitivity and specificity of the algorithm against experts was 96% (95% CI:91%-100%) and 95% (95% CI:90%-99%), respectively, vs 77% (95% CI:68%-85%) and 99% (95% CI:96%-100%) against untrained clinicians, and 97% (95% CI:92%-100%) and 88% (95% CI:82%-94%) against trained clinicians. CONCLUSIONS & INFERENCES: An automated artifact detection and rejection algorithm was developed showing >95% sensitivity and specificity vs expert markers. This algorithm overcomes an important challenge in the clinical translation of BSGM and is now being routinely implemented in patient test interpretations.
15
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Pitfalls in the analysis of electrogastrographic recordings
M.A.M.T. Verhagen, Leonard J. van Schelven, Melvin Samsom et al. · Gastroenterology · 1999 · 168 citations · Full text
Armen A. Gharibans, Todd P. Coleman, Hayat Mousa et al. · Clinical Gastroenterology and Hepatology · 2019 · 139 citations · Full text