ACS Applied Materials & Interfaces · 2022 · 26 citations · 20 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingDiagnostic ImagingNanomaterialsContrast AgentsContrast MediaMagnetic Resonance Contrast MechanismsNanomedicineNanoparticle DesignVascular ImagingBioimaging NanomaterialsContrast Agent RelaxivityContrast EnhancementExtravasation MechanismsHydrodynamic DiameterMolecular Contrast AgentsNanoparticle Contrast AgentsNanoparticle Imaging Probes
Enhanced angiography based on magnetic resonance imaging (MRI) has emerged as a noninvasive, robust, and high-resolution imaging technique for the clinical evaluation of vascular diseases. However, the effects of clinical Gd-chelating contrast agents are unsatisfactory for MRI contrast enhancement owing to their short blood half-life caused by rapid vascular extravasation, especially in microvessels. To address these issues, nanoprobes based on red blood cell membrane-coated ultrasmall NaGdF4 nanoparticles that exhibit much higher longitudinal molar relaxivity (r1) than the clinically used contrast agent gadolinium diethylenetriaminepentaacetic acid have been developed. Furthermore, the appropriate hydrodynamic diameter and stealth nature aid the nanoprobes to reside longer within the blood vessels without extravasation, thereby increasing the contrast between the blood vessels and surrounding tissues. Through probe-enhanced three-dimensional (3D) dynamic contrast-enhanced MR angiography, the main arteries and veins of the mouse were readily discernible, and even tiny vessels with sub-millimeter diameters could be clearly depicted. With this level of outstanding MR angiography performance, the embolization and recanalization processes of the carotid artery can be serially monitored with high imaging resolution using only a single injection. Additionally, the results of clearance studies and the toxicity tests further highlight the safety features of the nanoprobe. To summarize, the nanoprobes used in this study exhibit less extravascular leakage and a longer blood half-life, thus successfully overcoming the defects of the conventional low-molecular-weight Gd-based contrast agents and demonstrating their potential usefulness in enhanced MR angiography.
20
Role of CD47 as a Marker of Self on Red Blood Cells
Per‐Arne Oldenborg, Alex Zheleznyak, Yifu Fang et al. · Science · 2000 · 1.9K citations
Byung Hyo Kim, Nohyun Lee, Hyoungsu Kim et al. · Journal of the American Chemical Society · 2011 · 942 citations
Natural Sciences, Materials Engineering, Materials Science +17
Coronary Magnetic Resonance Angiography for the Detection of Coronary Stenoses
Won Yong Kim, Peter G. Danias, Matthias Stuber et al. · New England Journal of Medicine · 2001 · 903 citations
Medicine, Cardiology, Radiology +14
Cloaking nanoparticles with protein corona shield for targeted drug delivery
Jun Yong Oh, Han Sol Kim, L. Palanikumar et al. · Nature Communications · 2018 · 404 citations · Full text