Frontiers in Cardiovascular Medicine · 2022 · 10 citations · 41 references
MedicineCardiologySurgeryBiomedical ImagingClinical CardiologyInterventional CardiologyAcute Coronary Syndrome InterventionCoronary AngioplastyCoronary Artery DiseaseIschemic Heart DiseasePercutaneous Coronary InterventionStent PlacementCoronary Lesion AssessmentCoronary StentingCulprit Lesion RevascularizationSafety Endpoint AnalysisSafety Endpoint AssessmentStent Patency AssessmentTissue Healing ResponseVascular Healing
Background The healing response of the Firehawk stent in patients with ST-segment elevation myocardial infarction (STEMI) remains unclear. Aim We compared the vascular healing of a biodegradable polymer sirolimus-eluting stent (Firehawk) vs. a durable polymer everolimus-eluting stent (Xience) at 6 months after percutaneous coronary intervention (PCI) in patients with STEMI. Methods In this prospective, multicenter, randomized, non-inferiority study, patients within 12 h of STEMI onset were randomized in a ratio of 1:1 to receive Firehawk or Xience stents. Optical coherence tomography (OCT) follow-up was performed 6 months after the index procedure and assessed frame by frame. The primary endpoint was the neointimal thickness (NIT) at 6 months evaluated by OCT. The safety endpoint was target lesion failure (TLF) at 12 months. Results The Firehawk stent was non-inferior to the Xience stent in terms of the neointimal thickness (73.03 ± 33.30 μm vs. 78.96 ± 33.29 μm; absolute difference: −5.94 [one-sided 95% lower confidence bound: −23.09]; P non−inferiority < 0.001). No significant difference was observed between the Firehawk and Xience groups regarding the percentage of uncovered struts (0.55 [0.08, 1.32]% vs. 0.40 [0.21, 1.19]%, P = 0.804), the percentage of malapposed struts (0.17 [0.00, 1.52]% vs. 0.17 [0.00, 0.69]%, P = 0.662), and the healing score (1.56 [0.23, 5.74] vs. 2.12 [0.91, 3.81], P = 0.647). At 12 months, one patient in the Firehawk group experienced a clinically indicated target lesion revascularization. No other TLF events occurred in both groups. Independent risk factors of the NIT included body mass index, hyperlipidemia, B2/C lesions, thrombus G3–G5, thrombus aspiration, and postdilation pressure. Conclusion In patients with STEMI, Firehawk was non-inferior to Xience in vascular healing at 6 months. Both stents exhibited nearly complete strut coverage, moderate neointimal formation, and minimal strut malapposition. Clinical Trial Number NCT04150016.
41
2018 ESC/EACTS Guidelines on myocardial revascularization
Franz‐Josef Neumann, Miguel Sousa‐Uva, Anders Ahlsson et al. · European Heart Journal · 2018 · 7.1K citations · Full text
Clinical End Points in Coronary Stent Trials
Donald E. Cutlip, Stephan Windecker, Roxana Mehran et al. · Circulation · 2007 · 5.4K citations
Pathology of Drug-Eluting Stents in Humans
Michael Joner, Aloke V. Finn, Andrew Farb et al. · Journal of the American College of Cardiology · 2006 · 2.7K citations
Medicine, Cardiology, Pathology +11
Pathological Correlates of Late Drug-Eluting Stent Thrombosis
Aloke V. Finn, Michael Joner, Gaku Nakazawa et al. · Circulation · 2007 · 1.3K citations · Full text