Journal of Refractive Surgery · 2022 · 17 citations · 18 references
MedicineOphthalmologySurgeryOcular DiseaseOphthalmic SurgeryRefractive SurgeryCataract SurgeryComplications Of Refractive SurgeryHyperopia CorrectionRefractive ErrorRetinal SurgerySmall Incision Lenticule ExtractionFemtosecond Laser PulsesFemtosecond Laser UseHyperopic CorrectionHyperopic Small Incision Lenticule ExtractionLenticule Extraction TechniqueSpherical Aberration CorrectionSpherical Equivalent RefractionUncorrected Visual Acuity
PURPOSE: To report the long-term clinical experience following femtosecond intrastromal lenticule implantation (FILI) for the management of moderate to high hyperopia. METHODS: Eligible patients who underwent FILI for moderate to high hyperopia from July 2013 to October 2020 were included. A donor small incision lenticule extraction lenticule, matched for refractive error, was implanted into the recipient's corneal pocket created using a femtosecond laser at 160 µm depth. Visual and refractive outcomes and long-term complications were evaluated at the end of a mean follow-up of 68 ± 17.28 months (5.6 years). RESULTS: Forty-two eyes of 25 patients (mean age: 27.29 ± 5.52 years) were analyzed. The mean spherical equivalent reduced significantly from +5.50 ± 1.96 to +0.66 ± 1.17 diopters (D) at last follow-up visit. Thirty eyes (71%) were within ±1.00 D of spherical equivalent correction. Cumulative uncorrected distance visual acuity of 20/40 or better was achieved in 34 eyes (81%). Efficacy and safety indices were 0.86 ± 0.19 and 1.17 ± 0.39, respectively. There was a significant increase in mean keratometry (Kmean) anterior, central corneal thickness, Q-value, and corneal higher order aberrations and a decrease in Kmean posterior 2 weeks postoperatively, without any significant change in these parameters thereafter ( P > .05). Four eyes of 3 patients underwent enhancement and another 4 eyes underwent explantation of the lenticule followed by exchange (2 eyes) and hyperopic laser in situ keratomileusis (2 eyes). No eye lost more than one line of CDVA. CONCLUSIONS: At 5 years of follow-up, FILI for moderate to high hyperopia showed good safety, efficacy, and reversibility. Modification of nomograms and surgical planning may be employed for further refinement of the outcomes. [ J Refract Surg. 2022;38(6):348–354.]
18
Kishore Raj Pradhan, Dan Z. Reinstein, Glenn I. Carp et al. · Journal of Refractive Surgery · 2013 · 187 citations
Medicine, Ophthalmology, Surgery +15
The Safety and Predictability of Implanting Autologous Lenticule Obtained by SMILE for Hyperopia
Ling Sun, Peijun Yao, Meiyan Li et al. · Journal of Refractive Surgery · 2015 · 141 citations
Medicine, Ophthalmology, Surgery +17
Soosan Jacob, Dhivya Ashok Kumar, Amar Agarwal et al. · Journal of Refractive Surgery · 2017 · 96 citations
Medicine, Ophthalmology, Surgery +16