NeuroImage · 2022 · 51 citations · 27 references
Life SciencesNeurologyNeuroscienceMass Spectrometric AnalysisMetabolomicsNeurochemistryBrain ImagingFunctional NeuroimagingMagnetic Resonance ImagingMagnetic Resonance SpectroscopyMetabolite ProfilingMetabolite QuantificationData HarmonizationFunctional MriImaging Data HarmonizationIn Vivo Nmr SpectroscopyNuclear Magnetic Resonance QuantificationNuclear Magnetic Resonance Spectroscopy Data AnalysisNuclear Magnetic Resonance Spectroscopy-based Metabolite ProfilingStandardization In Metabolite Profiling
Magnetic resonance spectroscopy (MRS) is a non-invasive neuroimaging technique used to measure brain chemistry in vivo and has been used to study the healthy brain as well as neuropathology in numerous neurological disorders. The number of multi-site studies using MRS are increasing; however, non-biological variability introduced during data collection across multiple sites, such as differences in scanner vendors and site-specific acquisition implementations for MRS, can obscure detection of biological effects of interest. ComBat is a data harmonization technique that can remove non-biological sources of variance in multisite studies. It has been validated for use with structural and functional MRI metrics but not for MRS measured metabolites. This study investigated the validity of using ComBat to harmonize MRS metabolites for vendor and site differences. Analyses were performed using data acquired across 20 sites and included edited MRS for GABA+ (N = 218) and macromolecule-suppressed GABA data (N = 209), as well as standard PRESS data to quantify NAA, creatine, choline, and glutamate (N = 190). ComBat harmonization successfully mitigated vendor and site differences for all metabolites of interest. Moreover, significant associations were detected between sex and choline levels and between age and glutamate and GABA+ levels that were not detectable prior to harmonization, confirming the importance of removing site and vendor effects in multi-site data. In conclusion, ComBat harmonization can be successfully applied to MRS data in multi-site MRS studies.
27
Harmonization of cortical thickness measurements across scanners and sites
Jean‐Philippe Fortin, Nicholas Cullen, Yvette I. Sheline et al. · NeuroImage · 2017 · 1.6K citations
Medicine, Neuroscience, Radiology +12
Harmonization of multi-site diffusion tensor imaging data
Jean‐Philippe Fortin, Drew Parker, Birkan Tunç et al. · NeuroImage · 2017 · 1.3K citations · Full text
Medicine, Neuroscience, Radiology +17
Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris et al. · Journal of Magnetic Resonance Imaging · 2013 · 668 citations · Full text