IEEE Transactions on Biomedical Circuits and Systems · 2022 · 28 citations · 67 references
EngineeringBiomedical EngineeringElectrical EngineeringElectrophysiologyNeural EngineeringSystems NeuroscienceBrain-computer InterfacesImplantable Neural DevicesMicroelectrode ArraysNeural DecodingNeural InterfacesNeural Signal ProcessingBrain-machine InterfacesImplantable Neural InterfacesIntracortical Brain-computer InterfacesIntracortical InterfacesIntracortical Microelectrode ArraysNeural RecordingNeural Recording SystemsPower Consumption
Intracortical brain-machine interfaces have shown promise for restoring function to people with paralysis, but their translation to portable and implantable devices is hindered by their high power consumption. Recent devices have drastically reduced power consumption compared to standard experimental brain-machine interfaces, but still require wired or wireless connections to computing hardware for feature extraction and inference. Here, we introduce a Neural Recording And Decoding (NeuRAD) application specific integrated circuit (ASIC) in 180 nm CMOS that can extract neural spiking features and predict two-dimensional behaviors in real-time. To reduce amplifier and feature extraction power consumption, the NeuRAD has a hardware accelerator for extracting spiking band power (SBP) from intracortical spiking signals and includes an M0 processor with a fixed-point Matrix Acceleration Unit (MAU) for efficient and flexible decoding. We validated device functionality by recording SBP from a nonhuman primate implanted with a Utah microelectrode array and predicting the one- and two-dimensional finger movements the monkey was attempting to execute in closed-loop using a steady-state Kalman filter (SSKF). Using the NeuRAD's real-time predictions, the monkey achieved 100% success rate and 0.82 s mean target acquisition time to control one-dimensional finger movements using just 581 μW. To predict two-dimensional finger movements, the NeuRAD consumed 588 μW to enable the monkey to achieve a 96% success rate and 2.4 s mean acquisition time. By employing SBP, ASIC brain-machine interfaces can close the gap to enable fully implantable therapies for people with paralysis.
67
Neuronal ensemble control of prosthetic devices by a human with tetraplegia
Leigh R. Hochberg, Mijail D. Serruya, Gerhard M. Friehs et al. · Nature · 2006 · 3.3K citations
High-performance neuroprosthetic control by an individual with tetraplegia
Jennifer L. Collinger, Brian Wodlinger, John E. Downey et al. · The Lancet · 2012 · 1.9K citations
Learning to Control a Brain–Machine Interface for Reaching and Grasping by Primates
Jose M. Carmena, Mikhail Lebedev, Roy E. Crist et al. · PLoS Biology · 2003 · 1.8K citations · Full text
Cortical control of a prosthetic arm for self-feeding
Meel Velliste, Sagi Perel, M. Chance Spalding et al. · Nature · 2008 · 1.6K citations