Interand Intraindividual Variation in Doppler Ultrasonic Indirect Blood Pressure Measurements in Healthy Cats

Andy Sparkes, Sarah Caney, Matthew C. King, T.J. Gruffydd‐Jones

Journal of Veterinary Internal Medicine · 1999 · 42 citations · 13 references

DOIFull text

Open access

Concepts

Abstract

Abstarct This study was undertaken to evaluate reference ranges for systolic blood pressure (SBP) in cats under conditions mimicking a clinical setting. SBP was measured in 50 healthy adult cats of various ages (range, 1.5–16 years) and body weights (range, 2.2–6.1 kg) by Doppler ultrasonic sphygmomanometry. A cuff width of 2.5 cm was used, placed on the left antebrachium, and this represented a mean cuff width of 35% limb circumference (range, 31–42%). The mean (6SD) SBP in the 50 cats was 162 ± 19 mm Hg (range 124–210), with only 1 cat having a SBP ≤ 200 mm Hg. No significant difference (P > .05) in SBP was found between male and female cats, and no significant correlation was found between SBP and age (rs= 0.075) or body weight (rs= 0.007). Further studies in some of these cats indicated that allowing a period of 10 minutes for acclimatization to the environment where SBP was recorded resulted in a significant decrease in SBP from 176 ± 17 to 157 ± 21 mm Hg (n = 7) and that use of a 3.3-cm-width cuff resulted in a significant decrease in measured SBP from 168 ± 13 to 164 ± 13 mm Hg (n = 10). Reproducibility of SBP measurements was evaluated in 7 cats by assessing SBP 7 times at intervals of ≤24 hours over a 10-day period. These 7 cats had a low intraindividual coefficient of variation of SBP measurements (CV ≥ 7.9%) although 2 of the 7 cats had SBP values .200 mm Hg on at least 1 occasion.