European Transactions on Electrical Power · 1998 · 22 citations · 15 references
EngineeringElectrical EngineeringBuilding DiagnosticsCondition AssessmentDiagnostic ReasoningCondition MonitoringDiagnosisDiagnosticsFault DetectionFault DiagnosisInduction MachinesBearing FaultsBroken Rotor Bar DetectionElectric Motor Fault DiagnosisInduction MotorsMachine Condition MonitoringMotor Condition MonitoringMotor Fault DiagnosisRotor Bar Faults
Abstract The study gives a synopsis over condition monitoring methods both as a diagnostic tool and as a technique for failure identification in high‐voltage induction motors. Methods of fault detection are reviewed and analyzed: mechanical (vibrations, shock pulses, acoustic, speed fluctuations), electro‐mechanical (currents, surges, partial discharges, leakage fluxes) and temperature‐, oil particle‐, gas analysis, and performance‐ and visual methods. The study indicates how different types of faults generate different frequency components in vibration spectra, in motor supply current, in torque and in magnetic field, and relationships between fault types and spectra have been developed. Supply current waveform analysis has been applied to demonstrate the detection of broken rotor bars and bearing faults.
15