Oxidation of Tritium Gas in Glovebox Atmosphere using CuO Column

Masabumi Nishikawa, Takashi ISAYAMA, Kohsuke SHINNAI

Journal of Nuclear Science and Technology · 1983 · 12 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

A multiple barrier containment concept for tritium control is proposed to provide minimal release to the environment. The rationale for this design is the prevention of the dilution of tritium within each barrier so that the tritium can be recovered before it penetrates to the outer barrier. Oxidation performances of CuO sponge column in the inert atmosphere of glovebox system are discussed and following results are obtained. The oxidation column efficiency or KFaVcat/Q plays an important role in the tritium level decrease on the glovebox atmosphere. The recommended value of the column efficiency is 20–100. The isotope effect in chemical oxidation of H2, D2 and HT is 1, 1/6 and 1/12, respectively. Use of CuO sponge for the atmosphere in the presence of oxygen is not recommended because of the retardation of chemical oxidation rate.